p. 94 Esmach S.p.A. Grisignano di Zocco (VI) - I
SPI 30-200 F
Instructions for use
and maintenance
By pressing the button (16) twice, the water supply is set to zero, the displays (2) and (5) show the initial
values again.
When the water dosage is completed, the system switches to the previous mixture program automatically
(automatic from 0 to 9).
The values of litres and decilitres remain set up even if you switch from the mixture program and then you
come back to “W” program.
IMPORTANT NOTICE!
If during the dispenser, the voltage is lacking/missing, the count of the litres remains stored; when
the tension is re-established, the display (2) and (5) blink.
Press the button (15) to complete the dosage cycle
, in this case take into account that the water
temperature might have changed considerably,
or press the button (16) to terminate it
.
In dispenser mode, each output signal is deactivated for the operating of the bowl and spiral arm, which
remain still.
The parameter P12 (see par. 3.3.5.6) allows to set the max.value of litres to supply for each water dosage
cycle; this parameter is adjusted according to the bowl capacity ( see table and picture below)
MACHINE
LITRE MAX. VALUE TO SET FOR
PARAMETER P12
SPI 60 E
60
SPI 80 E
80
SPI 100 E
100
SPI 130 E
130
SPI 160 E
160
SPI 200 E
200
3.3.5.5
( “E ” VERSION ONLY ) PROGRAMMING STEPS SUMMING UP
In presence of the machine with infra-red temperature probe, D1 and D2 dispenser, the following setting
parameter sequence is given when the system is in programming mode:
-
no. of programs
: through the button (9) choose the number of the program needed (from 0 to 9) on the
display (8):
Set the the 1
st
and 2
nd
speed operating time on (2) and (5) through the keys -/+
concerned
- mixture temperature:
press (9) (the display (8) blinks), and then set up the temperature value needed
through the keys -/+
-
D1 dispenser
: press (9) ( the display (2) shows “_d1”), then set up the dosage time for D1 on the display
(5) through the keys -/+ concerned .
-
D2 dispenser
: press (9) (the display (2) shows “_d2”), then set up the dosage time for D2 on the display
(5) through the keys -/+ concerned