p. 106 Esmach S.p.A. Grisignano di Zocco (VI) - I
SPI 30-200 F
Instructions for use
and maintenance
4.5
ADJUSTMENT AND REPLACEMENT OF MICROSWITCH CONNECTED TO BOWL COVER
Picture 24 – Safety Microswitch connected to Bowl Cover
With reference to Picture Picture 24, the safety microswitch (1) coupled with the cover (2) is fixed on the
support (3) with two screws (4) and two nuts (5) (these latter coupled with unscrewing washers ). If for any
reason it needs to be replaced, it is sufficient to disconnect the cables, remove the screws (4) and the nuts
(5), and washers concerned, to disassemble it. The new microswitch (1) is and has to be electrically
connected by a qualified electrician only, skilled in board machine electrical equipment.
The microswitch has to operate with contacts normally closed ( forced opening of the contact by opening the
cover).
2
1
3
5
4
6
7
8
9
5
SPI 60 - 80 -
10
SPI 30-45
SPI 130 - 160 -