T3-B T6-B Manipulator 12. Standard I/O Connector
110
T-B series Rev.1
12. Standard I/O Connector
CAUTION
Be careful not to exceed rated current range or rated current which are defined
in manual.
If exceeding rated current, the Manipulator may now operate at worst.
Standard I/O Connector is a connector mounted on back side of the Manipulator for
connecting your input/output equipment to the system.
Connector name
Pins
Bit number
I/O (Input) Connector
18
0-17
I/O (Output) Connector
12
0-11
For cable wiring, refer to “
3.7.2 Noise Countermeasures
” in order to prevent noise.
Remote function is initially assigned to both input and output from 0 to 8. For further details,
refer to “
14. I/O Remote Settings
”.
Also, for details of hand I/O, refer to “
13.Hand I/O Connector
”.
12.1 Input Circuit
Input Voltage Range
: +12 to 24 V
±
10%
ON Voltage
: +10.8 V (min.)
OFF Voltage
: +5 V (max.)
Input Current
: 10 mA (TYP) at +24 V input
Two types of wiring are available for use with the two-way photo coupler in the input circuit.
Summary of Contents for T-B Series
Page 1: ...SCARA ROBOT T B series MANUAL Rev 1 EM217R4788F ...
Page 2: ...SCARA Robots T B series Manual Rev 1 ...
Page 16: ...TABLE OF CONTENTS xiv T B series Rev 1 ...
Page 18: ......
Page 40: ...Installation 5 Second Step 24 T B series Rev 1 ...
Page 42: ......
Page 58: ...T3 B T6 B Manipulator 2 Specifications 42 T B series Rev 1 2 3 Outer Dimensions 2 3 1 T3 B ...
Page 59: ...T3 B T6 B Manipulator 2 Specifications T B series Rev 1 43 2 3 2 T6 B ...
Page 77: ...T3 B T6 B Manipulator 3 Environments and Installation T B series Rev 1 61 T6 B A B ...
Page 158: ...T3 B T6 B Manipulator 18 Error Code List 142 T B series Rev 1 ...
Page 160: ......
Page 168: ......
Page 178: ...Appendix B Time and Distance of Free Running in Emergency 162 T B series Rev 1 ...
Page 182: ...Appendix C Time and Distance of Free Running When Safeguard Is Opened 166 T B series Rev 1 ...