SC-F7000 Serie/SC-B7000 Series
Revision A
ADJUSTMENT
Overview
88
Confidential
CR related
parts/units
CR Encoder
After
replacement
11 Manual Bi-d adjustment
√
PGPP
√
√
12 Reset the encoder counter.
√
√
---
Print Head
Before
replacement
1
Turn the power on in normal mode.
---
√
---
2
Dispose of waste ink.
---
√
---
3
Reset the waste ink counter (Maintenance menu)
---
√
---
4
Activate the ink cartridges for service.
√
√
---
5
Turn the power off.
---
√
---
6
Remove the ink tanks.
---
√
---
7
Install the ink cartridges for service.
---
√
---
8
Turn the power on in Serviceman mode.
---
√
√
9
Tube inner pressure reduction
√
√
√
10 Auto CR unlock & move CR to full column side
√
√
√
Replacement
11 Replacement
---
√
√
After
replacement
12 Turn the power on in Serviceman mode.
---
√
---
13 Reset the Print Head Counter.
√
√
---
14 Head ID Input
√
√
---
15 Turn the power off.
---
√
---
16 Turn the power on in normal mode.
---
√
√
17 Setting [0 RIP Settings]
---
√
√
18 Load the media.
---
PGPP
√
√
19 Cleaning (CL3)
√
√
√
20 Nozzle Check
√
PGPP
√
√
21 Head inclination manual adjustment (CR direction)
√
PGPP
√
√
22 Head slant manual adjustment (PF direction)
√
PGPP
√
√
23 Turn the power off.
---
√
√
24 PG Adjustment
---
Thickness gauge
√
√
25 Turn the power on in normal mode.
---
√
√
26 Manual Uni-d adjustment
√
PGPP
√
√
27 Manual Bi-d adjustment
√
PGPP
√
√
Table 4-1. Adjustment items and the order by repaired part
Class
Replaced or Repaired
(Reattached) Part/Unit
Required Operations
Service
Program
Jig
Media
Replaced
Reattached
Page
Summary of Contents for SC-B7000 Series
Page 6: ...Confidential Revision Status Revision Date of Issue Description A March 14 2013 First release ...
Page 9: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Page 42: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 84: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Page 123: ...Confidential C H A P T E R 5 MAINTENANCE ...