SC-F7000 Serie/SC-B7000 Series
Revision A
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
67
Confidential
11. Remove the FFC clamp.
12. Remove the three screws, and remove the Print Head.
C) Silver M3x8 screw (Bit No.1): 3 pcs
13. Disconnect the Head FFCs from the Print Head.
Figure 3-22. Removing the Print Head
14. Reassemble the printhead and other parts by reversing the disassembly procedure.
AFTER REPLACEMENT
1. Start the printer in the Serviceman Mode.
Turn on the printer while pressing
[Menu] + [Back] + [OK]
.
2. Select
Printer Head Counter
.
Press the
[Run]
button to reset the counter.
Figure 3-23. [Printer Head Counter] screen
Make sure to connect the Head FFCs straight and all the way in the
connector.
Print Head
C
C
C
Head FFCs
CR Unit
FFC clamp