8.4.2.4 Timing of Being Selected
Symbol Specification Min.
Typ.
Max.
Unit
T
217
SELID valid - XSBSY(IN)
↑
0
-
- ns
T
218
XSBSY(IN)
↑
- XSBSY(OUT)
↓
800 -
- ns
T
219
XSBSY(OUT)
↑
- XSSEL
↑
0
- - ns
T
220
XSSEL
↓
- XSBSY(OUT)
↑
-
- 200 ns
XSBSY(IN)
XSSEL
XSBSY(OUT)
XSDB0-7,P
XSIO
T
218
T
219
T
220
T
217