S1R72105 Technical Manual
78
EPSON
Rev.1.0
8.4.2.11 Target Asynchronous Data-out Timing (Data input)
Symbol Specification Min.
Typ.
Max.
Unit
T
243
XSDB valid - XSACK
↓
30
-
- ns
T
244
XSACK
↓
- XSREQ
↑
25
-
90
ns
T
245
XSREQ
↑
- XSDB invalid
0
- - ns
T
246a
XSACK
↑
- XSREQ
↓
25
- - ns
T
246b
XSREQ
↑
- XSREQ
↓
150
-
- ns
XSDB0-7,P
XSREQ
XSACK
T
243
T
245
T
244
T
246a
T
246b