2. Installation
66
RC700 / RC90 Option Fieldbus I/O Rev.14
Setting on slave side
27.
Right-click [netDevice]-<EPSON TSERIES…> icon.
Select [Configuration…].
28.
The [Configuration] dialog box appears.
29.
Select [Configuration]-[Connection]-[Poll] tab.
30.
Enter the settings of the slave side and click <OK>.
Poll connection configuration
Item
State
Consumption
Checked
Consumption - Size
20
Consumption - Connection Path
User Defined Consumption Data
Production
Checked
Production - Size
20
Production - Connection Path
User Defined Production Data
31.
Close the [Configuration] dialog box.