4. Troubleshooting (DeviceNet)
RC700 / RC90 Option Fieldbus I/O Rev.14
289
Status Code
Descriptions
General Protocol
45
Non-resident dialogue software.
Additional information:
Initialize the applicomIO® interface before use by
running the PcInitIO
47
Targeted applicomIO® card invalid or incorrectly
initialized by the function IO_Init
53
Synchronization problem on the line.
Additional information:
The DeviceNet master is “off line” (power supply
not detected or the CAN component of the
applicomIO® is “Bus Off”)
Check the network wiring and Baud Rate.
55
Response time-out exceeded.
Additional information:
The device accepted the connection but did not
respond the request.
Check the device status.
65
Connection denied.
Additional information:
Connection to the DeviceNet master is in progress
or refused by the device.
70
Connection finished.
Additional information:
Duplication of MAC ID detected on the DeviceNet
network.
Modify the MAC ID of the DeviceNet master.
79
Profile incompatible.
Additional information:
The device does not match the configuration.
Check the device identity and the connection sizes.
63
Indicates that a communication error has been
encountered on serial Port.
66
Not enough applicomIO® interface memory.
93
Driver cannot be accessed.
99
Indicates that applicomIO® solution is already
running.
255
Indicates that the local input buffer was not updated
beforehand by the function IO_RefreshInput.
Summary of Contents for RC700
Page 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Page 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...