![Epson RC700 Manual Download Page 43](http://html.mh-extra.com/html/epson/rc700/rc700_manual_106988043.webp)
2. Installation
RC700 / RC90 Option Fieldbus I/O Rev.14
31
Installing a Board
WARNING
Make sure that the power is turned OFF before installing/removing any boards or
connecting/disconnecting any cables. Working with the power ON is extremely
hazardous and may result in electrical shock and/or malfunction of equipment.
1. Configure the board address jumper (JP1) on DeviceNet master board manufactured
by molex.
You can install one Fieldbus master board to the PC with the EPSON RC+ 7.0
installed.
The board number should be “1”.
Refer to the following table for JP1 configuration.
Short Socket
Board No.
C0
C1
C2
1
0: Short
0: Short
0: Short
2. Install the DeviceNet master board manufactured by molex to the PCI bus of the PC
with the EPSON RC+ 7.0 installed. Installation methods of the DeviceNet master
board manufactured by molex to the PCI bus and how to open the cover differ
depending on the type of PC. Refer to the manuals of each PC on how to install the
board to the PCI bus.
3. Connect the DeviceNet master board manufactured by molex with the DeviceNet
network.
4. Start up the PC.
5. Open the [applicomIO Console] installation folder and start the “applicomIO Console”
application.
Following is specified for [applicomIO Console] installation folder as default.
C:\Program Files(x86)\BradCommunications\applicomIO\4.1
6. The [applicomIOR console] dialog box appears. Add the DeviceNet master board
manufactured by molex.
Click <Add Board>.
Summary of Contents for RC700
Page 1: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 EM198C4088F ...
Page 2: ...Robot Controller RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 8: ...vi RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 12: ...Table of Contents x RC700 RC90 Option Fieldbus I O Rev 14 ...
Page 340: ...5 Maintenance Parts List 328 RC700 RC90 Option Fieldbus I O Rev 14 ...