Ethernet port
The RJ45 LAN/Ethernet port on the rear side of the device is provided for
communication with the device in terms of remote control or monitoring. The
user has basically two options of access:
1. A website (HTTP, port 80) which is accessible in a standard browser via the
IP or the host name given for the device. This website offers a configuration
page for network parameters, as well as an input box for SCPI commands to
control the device remotely by manually entering commands.
2. TCP/IP access via a freely selectable port (except 80 and other reserved
ports). The standard port for this device is 5025. Via TCP/IP and the selected
port, communication to the device can be established in most of the common
programming languages.
Using the Ethernet port, the device can either be controlled by commands from
SCPI or ModBus protocol, while automatically detecting the type of message.
The network setup can be done manually or by DHCP. Transmission speed and duplex mode are on automatic mode.
If remote control is in operation the Ethernet port has no priority over any other interface and can, therefore, only
be used alternatively to these. However, monitoring is always available.
1.9.14
Water cooling
Contrary to the standard air-cooled versions of the models in this series, water cooling is optionally available. It’s
built in during the manufacturing process, so retrofitting isn’t possible. Cooling the device with water instead of air
cooling comes with a few advantages:
•
Less ambient noise generated by the device (no fans running)
•
Better cooling at higher ambient temperatures
•
No direct dissipation of heat into the ambiance of the device
However, there also disadvantages:
•
The device isn’t allowed to run under load without active water flow
•
Water flow inside an electronic device includes a higher risk of damage caused by a leak or by condensation of
water from air humidity (dewing)
The water taps are located on the rear side of the device, also see the rear view drawing in section
. Details
about the connection, requirements and use of the water cooling can be found in section