PSI 10000 4U Serie
IF Settings
Description
Profibus
Node Address
Selection of the Profibus or node address of the device within range 1...125 via
direct input
Function Tag
String input box for a user-definable text which describes the Profibus slave function
tag. Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profibus slave location
tag. Max. length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave instal
-
lation date tag. Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters
Manufacturer ID
Registered manufacturer ID with the Profibus organization
Ident number
Product identification number, same as in the GSD file
IF Settings
Description
Slot Ethernet, ModBus-TCP
(1 & 2 Port)
DHCP
The IF allows a DHCP server to allocate an IP address, a subnet mask and a gate
-
way. If no DHCP server is in the network then network parameters will be set as
defined below.
IP address
This option is activated by default. An IP address can be manually allocated.
Subnet mask
Here a subnet mask can be defined if the default subnet mask is not suitable.
Gateway
Here a gateway address can be allocated if required..
DNS address
Here the addresses of the first and second Domain Name Servers (DNS) can be
defined, if needed.
Port
Select port in the range 0...65535.
Default port:
5025
Reserved ports: 502 (ModBus TCP), 537
Host name
User definable host name (default:
Client
)
Domain
User definable domain (default:
Workgroup
)
Speed / Duplex Port 1
Manual selection of transmission speed (
10MBit
/
100MBit
) and duplex mode (full/
half). It’s recommended to use the
Auto
option and only revert to another option if
Auto fails.
Speed / Duplex Port 2
Different Ethernet port settings for 2-port modules are possible, as these include
an Ethernet switch
IF Settings
Description
Profinet/IO (1 & 2 Port)
Host name
Free choice of host name (default:
Client
)
Domain name
Free choice of Domain (default:
Workgroup
)
Function Tag
String input box for a user-definable text which describes the Profinet slave function
tag. Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profinet slave location
tag. Max. length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave instal
-
lation date tag. Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave. Max.
length: 54 characters
Station Name
String input box for a user-definable text which describes the Profinet station name.
Max. length: 200 characters