3.10.15.12 Reading the PV curve
The last PV curve (or table) which has been calculated during the simulation run can later be read from the device
via digital interface (partly or completely) or stored to USB stick. This can serve to verify the adjusted parameters.
When running mode DAY E/T or DAY U/I this makes less sense, because there the curve would re-calculated with
every processed index and the read curve would always be the one belonging to the last day trend curve point.
When reading the PV table, you will receive up to 4096 current values. The table data could be visualised in an
XY diagram in tools like Excel.
3.10.16
Remote control of the function generator
The function generator can be remotely controlled, but configuration and control of the functions with individual
commands is different from manual operation. The external documentation “Programming Guide ModBus & SCPI”
on the included USB stick explains the approach. In general the following items apply:
•
The function generator isn’t directly controllable via the analog interface; the only impact to the function run can
come from pin REM-SB switching the DC output off and on, which will also stop and restart the function
•
The function generator is unavailable if R mode (resistance) is activated