PSI 10000 4U Serie
Group
Parameters & description
Master-slave
Mode
Selecting
Master
or
Slave
enables the master-slave mode (MS) and defines the position for
the unit in the MS system. For details see section
“3.11.1. Parallel operation in master-slave
.
Termination resistor
Activates or deactivates the so-called bus termination of the digital master-slave bus via a
switchable resistor. Termination should be activation if required, usually when problems with
the master-slave bus operation occur.
Bias resistors
Additionally to the regular termination resistor there are two bias resistor to be activated if re
-
quired to help stabilize the bus further. Tap on the information symbol for a graphical depiction.
Backlight off after 60s
If activated, it will switch off the display’s backlight after 60 seconds of inactivity. This settings
is primarily intended for slave units where the display isn’t supposed to be permanently on.
It’s identical to the setting in menu
HMI setup
.
Initialize system
Tapping this touch area will repeat the initialization of the master-slave system in case the
detection of all slave units by the master was unsuccessful, so the system would have less
total power than expected, or has to be repeated manually in case the master unit couldn’t
detect a missing slave or one slave has failed.
USB logging
Log file separator format
Defines the format of CSV files generated from logging files (also see
and
). This
setting also affects other features where a CSV file can be loaded or saved.
•
US
= Comma as column separator (US standard for CSV files)
•
Default
= Semicolon as column separator (german/european standard for CSV files)
Logging with units (V,A,W)
CSV files generated from USB logging by default add physical units to values. This can be
deactivated here.
USB logging
Activates/deactivates logging to USB stick. For more information refer to
Logging interval
Defines the time between two records in the log file. Selection:
500 ms
,
1 s
,
2 s
,
5 s
Start/stop
Defines how the USB logging is started and stopped.
Manual
= Logging only starts and stops upon user interaction on the HMI, by accessing touch
button
in the quick menu.
At DC on/off
= Logging starts and stops with every change of state on the DC output, no
matter if caused by the user, software or a device alarm. Attention: Every next start will create
a new log file.
Reset / Restart
Reset device to defaults
This touch area will initiate a reset of all settings (HMI, profile etc.) to factory default.
Restart
Triggers a warm start