39
EN
8. Adjustment of the performance
SteamRock II Basic steam generators have a fast-tuning performance that can be adjusted to
the cabin size in a few seconds on-site.
The switching capacity is set by means of F-fuses (see Fig. 9) on the main terminal block.
Each F-fuse adjusts the power by 3 kW. An 18 kW model allows therefo-
re 18 / 15 / 12 / 9 / 6 / 3 kW power output. A 9 kW model allows respec-
tively 9 / 6 / 3 kW power output..
The adjustment of the power can be done with any fuse except F1.
The F1 fuse must always be switched on.
Figure 9 shows F1-F6 fuses in the 18 kW model. The 9 kW version featu-
res F1 - F3 respectively.
In order to reduce power, switch the fuse to the RIGHT. Each switch
equals to 3 kW power capacity. To increase power, switch the fuse back
LEFT to the “ON” position. All fuses are factory set to “on”.
Select the power output to match the cabin size. We recommend to
check the power requirement in advance and select the optimal set-
ting.
F-fuse in SteamRock II Basic
18 kW
Abb. 9
Example 1
Example 3
Example 4
Example 2
18 kW model
18 kW power activated
9 kW model
9 kW power activated
9 kWmodel
6 kW power activated
18 kW model
12 kW power activated
OFF
ON
F1
F2
F3
I
I
I
OFF
ON
F1
F2
F3
I
I
0
OFF
ON
F1
F2
F3
F4
F5
F6
I
I
I
I
I
I
OFF
ON
F1
F2
F3
F4
F5
F6
I
I
I
I
0
0
Summary of Contents for SteamRock II Basic