48
EN
Closing the vaporiser tank
Now mount the cover with heating spirals on the container. The assembly takes place in the reverse
order. Make sure that the silicone sealing ring fits the mounting holes so that the socket screws can
be screwed in. Please also note that the baffle plate (a) at the bottom of the container lid does not
bend. Reconnect the steam pipe on the coupling to the device.
Reconnect the heating spirals.
Check all screws for tightness before
commissioning. Connect the steam pipe
(b) to the bottom of the housing. Place the
flexible water pipe on the water inlet valve
and fix it with the hose clamps (c). Attach
the descaling hose (d) to the connection
nipple for the descaler.
Then check the water tank and all attach-
ments for leaks before recommissioning.
b
c
d
Equipment damage due to overheating
with incorrect connection.
Please make sure that the first heating spiral,
as marked on the right, is connected to the
same, colour-coded supply line.
a
NOTICE