5.3 Installation location requirements
The steam generator is only intended for installation outside of steam rooms and is connected to
the room via a steam pipe. The following climatic conditions must be met at the installation site:
Ambient temperature during operation 5°C to 40°C
Air humidity during operation 30% to 75% rel. air humidity
Storage temperature: 0°C to 60°C
Stable wall for installation as the total weight can equal approx. 45 kg.
Near the unit: Mains connection 400 V 3N AC, with standardised CEE plug sockets
(not with sing-
le-phase connection)
Drain outlet below the unit or in close proximity
Water supply line in close proximity
Length of steam pipe, max. 10 m
All pipelines and connections must be accessible for service.
The room in which the steam generator is installed should be as near to the steam room as pos-
sible so that the pipeline distances are as short as possible.
Steam room requirements
Floor drain
Air extractor so that temperature control works properly
Steam generator requirements
Stable wall
Mains connection (as per technical data)
Water connection
Drain outlet