29
EN
Rotate the steam pipe upwards and lay it in ascending order
Cut out the pre-punched opening for the ascending pipe in the housing.
1.
Loosen the nut on the steam pipe’s flexible joint.
2.
Loosen the two screws on the base plate used to fix the steam pipe and pull the steam pipe
out from the base plate.
3.
Rotate the steam pipe upwards and retighten the nut on the flexible joint.
4.
The possible connection of the fragrance dosing line should be placed as close as possible
to the steam nozzle in the falling segment.
5.
Important note:
The connection of the fragrance dosing line must not be installed in the
rising segment of the steam pipe. This can lead to fragrance residues getting into the water
tank and causing excessive foaming. This can cause overheating and equipment damage.
Lay the steam pipe so it descends towards the steam outlet without any sharp 90° bends.
Positioning the steam pipe correctly
Check the screws in the tubular heating elements and tighten as needed (SW 19).
Image shows 18 kW version
Steam pipe
Securing nut
Summary of Contents for SteamRock II Basic