NOTICE
Damage due to inadequate installation site
The steam generator may vibrate slightly when the water boils.
If the wall bearing capacity is insufficient or the wall is of poor quality, the steam generator
cannot be securely installed and may fall off.
Before installation, check the quality and bearing capacity of the wall intended for instal-
lation. The wall must be able to support a total weight of max. 45 kg.
Before installation, check how the steam pipe is to be laid. Standard routing leads the
line out from the steam generator downwards.
Measurements for installation
The following distances must be observed:
Distance bet-
ween drill holes
Horizontal: 420 mm
Vertikal: 535 mm
On the side to the
left and right
Min. 250 mm
Top
Min. 500 mm
Bottom
Approx 1000 mm
The space underneath the unit may not be
occupied by other installations.