35
EN
Risk of fire due to overload!
No external loads may be connected to
the main terminal block in the steam ge-
nerator! The terminals can overheat and
lead to fire.
6.5 SteamRock II Basic connection to EmoTouch 3 Sauna, EmoTec H, Econ H
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Emotec H / EmoTouch 3 / ECON H
N S1 Wb PE
N S1 Wb PE
L1 L2 L3 N N N N
L1 L1 L2 L2 L3 L3 N N N N N N N N
SteamRock II Basic
9,0 kW (3 x 16 A)
SteamRock II Basic
18,0 kW (3 x 32 A)
L1
L2
L3
N
PE (Gr)
400 V 3N AC 50 Hz
3 x 32 A + PE
L1 L2 L3 N PE (Gr)
400 V 3N AC 50 Hz
3 x 16 A + PE
PE
S1
N
Wb
Übrige Anschlüsse gemäß Gebrauchsanleitung
Additional connections according to the user manual
N A2 FR
AGR
ANC
E
25 26 27 28
N A2
FR
AGR
ANC
E
WM
Emotec H / EmoTouch 3 / ECON H
PE (Gr)
S1
N
Wb
Übrige Anschlüsse gemäß Gebrauchsanleitung
Additional connections according to the user manual
WM
PE
(Gr)
PE
(Gr)
PE
(Gr)
PE
(Gr)
PE
(Gr)
PE
(Gr)
32A / 16A
N
L1
L3
L2
PE (Gr)
Pre-assembled Cekon plug power supply
400 V 3N AC - 32 A / 16 A
Pay attention to provide the fuse protection on all power supply lines!
DANGER
Summary of Contents for SteamRock II Basic