60
Installation and Operating Instructions - SteamAttrac
EN Operation
Replacing the immersion heaters
1
Place the 2” gaskets on the threaded fittings of the heaters.
Ensure that there are no other objects between the threaded fittings
and the flange.
2
Clean the bushes and screw in the heaters.
3
Fill the tank with water by pouring it into the filler spout and ensure that
the immersion heaters are fitted tightly so there are no leaks.
Tighten the heaters, as needed, and check for leaks. If water can leak,
the 2” threaded fitting can also be sealed with a commercial Teflon
sealing tape or sealing thread.
4
NOTICE Ensure that the polarity is correct when plugging in the flat
plug. Incorrect polarity can lead to severe overload and damage to the
tubular heating element.
Plug the flat plug into the heaters again.