SteamAttrac - Installation and Operating Instructions
41
Mounting
4
Put the steam outlet in place and tighten by hand. The steam emission
outlet must face downward.
The steam outlet can be purchased separately as an accessory.
See the chapter on Accessories (optional),
Steam outlet, item no. 2001.5575
If you choose to install a different steam outlet, observe the relevant
installation instructions.
3.4
Electrical installation
DANGER
Risk of electric shock
A faulty electrical connection poses the risk of an elec-
tric shock. This risk also applies following completion
of the installation work.
If retrofitting is required, the steam generator’s
housing must only be opened by trained personnel.
Before working on the clamps for the connection terminal, all
current supply circuits must be switched off.
Electrical installation must only be carried out by a qualified and
licensed electrician.
The unit must be connected to the power supply according to
the circuit diagram and the terminal scheme.
25
29
G 1 1/4“
66,8
30,8
52
13,5