SteamAttrac - Installation and Operating Instructions
23
Identification
2.6
Technical data
Dimensions (W x H x D)
450 x 330 x 270 mm
Weight when empty
Approx. 18 kg
Water supply line (pres-
sure)
2–8 bar
Max. operating pressure
(bar)
Pressure-free system with relief valve
Vaporiser tank
Stainless steel
Overheating protection Safety temperature limiter with capillary tube sensor,
switches off and locks for all poles
Heating system
Internal screw-in immersion heaters
Emptying and cleaning
Semi-automatic descaling with liquid descaler.
Cau-
tion:
The descaler must not foam.
Drain outlet
1” pipe with 1” 2-way motorised ball valve
Water level monitoring Automatic by the integrated water level control panel,
automatic refilling of water
Control system
No control system, external control panel required
(Econ S2 recommended)
Water connection
3/4” external thread
Steam outlet
External thread, 1”
Outlets – connections
Mains connection,
external control panel connection
Protection class
Protection class I (protective conductor connection)
Power consumption
3.0 kW/4.0 kW/6.0 kW
Power supply
For 3.0 kW: 230 V N AC, 50/60 Hz
For 4.0 kW: 400 V 3N AC, 50/60 Hz
For 6.0 kW: 400 V 3N AC, 50/60 Hz
Min. pipe cross-section
For 3.0 kW: 3 x 1.5 mm²
For 4.0 kW: 5 x 1.5 mm²
For 6.0 kW: 5 x 1.5 mm²
Fuse
For 3.0 kW: 1 x 16 A
For 4.0 kW: 3 x 16 A
For 6.0 kW: 3 x 16 A