Service settings
6.1.10 Post-heating time
This setting is available only in humidity mode. It is used to define how
long the heater operates after humidity mode.
According to this setting, the sauna heater is switched on in Finnish mode
after humidity mode to dry the sauna.
This function should be used together with the fan to remove any remain-
ing humidity from the sauna more quickly. See also 6.1.8 Fan post-cycle
period,
90 and 6.1.11 Post-heating temperature,
Setting the post-heating time
1
Open the service settings.
See 6.1.1 Opening service settings,
2
Tap
and confirm the selection.
3
Set the value with
and
, and then confirm by pressing
.
The value can be set to any number between 0 and 30 minutes. The
interval is set to 30 minutes by the factory.
min
Setting
01. June 2019
After-heating time
30