EmoTouch 3 - Operating Instructions
107
Service settings
Rebooting after a malfunction when updating
1
Press the Reset button.
The software is restarted. The software version and the configuration
are not modified.
2
Repeat the update.
6.2.3 Exporting the operating data
You can have an EOS Saunatechnik GmbH technician check the error mes-
sages by loading the messages onto the memory card and sending the
card to EOS.
Exporting the operating data
1
Switch the off switch on the relay box to I.
2
Insert the memory card to export data.
See
3
Switch on the relay box again and wait approx. 30 seconds.
The operating data is automatically written to the memory card.
The operating data is written to the
LOG
folder with the file name
T3_[serial number]_Dat.json
.
4
Switch off the relay box again.
5
Remove the memory card.
It takes a few seconds for the system to detect the memory card and
write the data to it. Therefore, you should wait at least 30 seconds
before removing it again.
6
Replace the front panel.
7
Send the operating data to the service address.