
Environnement
S.A
AF22e
Duplication prohibited
APRIL 2016
3–34
When the alarm is cleared, the analyzer returns to its normal status, and the icon
replaces the icon
in the bottom left side.
3.4.2.9.
Set the analyzer in standby mode
To activate stand-by mode, the user double-clicks on/touches
which becomes
.
Standby mode is used to stop the pump while all the other controls remain in operation. To reactivate
the measurement mode, double-click / touch
.
When the analyzer is switched to standby mode, the status icon (in bottom left side of screen) is modified
to
indicating standby status. However, alarm or control indication is a priority.
Consequently, if the analyzer is switched to standby mode while in alarm or control is active, the alarm
icon
or control icon
will remain displayed and the standby icon
will not be displayed.
Under these conditions, to verify if the measurement or standby status is active, the user checks the
button
is red-outlined or not in the advanced function page.
3.4.2.10.
Set the analyzer in maintenance mode
To activate maintenance mode, the user double-clicks on/touches
which becomes
.
Maintenance mode activation is used to flag that the analyzer is in maintenance. When maintenance
mode is activated, the recorded data are tagged with a status mark: "Maintenance" appears next to the
concerned data when they are downloaded.
Double-click on/touch
to reactivate the measurement mode.
As the analyzer is switched to maintenance mode, the status icon in the left bottom side of the screen
changes to
indicating maintenance status. However, alarm or control indication is a priority.
Consequently, if the analyzer is switched to maintenance mode while in alarm or control is active, the
Summary of Contents for AF22e
Page 20: ...EnvironnementS A AF22e Duplication prohibited APRIL 2016 1 12 Page intentionally left blank...
Page 22: ...EnvironnementS A AF22e Duplication prohibited APRIL 2016 2 2 Page intentionally left blank...
Page 76: ...EnvironnementS A AF22e Duplication prohibited APRIL 2016 3 42...
Page 82: ...EnvironnementS A AF22e Duplication prohibited APRIL 2016 4 2 Page intentionally left blank...
Page 98: ...EnvironnementS A AF22e Duplication prohibited APRIL 2016 4 18 Page intentionally left blank...
Page 100: ...EnvironnementS A AF22e Duplication prohibited APRIL 2016 5 2 Page intentionally left blank...
Page 107: ...Duplication prohibited AF22e EnvironnementS A APRIL 2016 5 9 Page intentionally left blank...
Page 118: ...EnvironnementS A AF22e Duplication prohibited JUNE 2016 5 20 Page intentionally left blank...