Art-Net
An Art-Net trigger can be unicast or broadcast to the
S-Play.
The Trigger will be activated, when the
incoming value is equal or greater than the
Art-Net channel parameters defined.
To avoid clashes do not use a universe
assigned for Recording/Playback.
When used in a playlist, the S-PLAY will wait
to receive the Trigger below before
continuing.
sACN
The Trigger will be activated, when the
incoming value is matched to the sACN
channel parameters defined.
To avoid clashes do not use a universe
assigned for Recording/Playback.
When used in a playlist, the S-PLAY will wait
to receive the Trigger below before
continuing.
DMX
The Trigger will be activated, when the
incoming value is matched to the DMX
settings defined.
To avoid clashes do not use a universe
assigned for Recording/Playback.
When used in a playlist, the S-PLAY will wait
to receive the Trigger below before
continuing.
N.B.
If DMX is selected as output protocol in the setting
page, the DMX triggers will be disabled in the playlist.