S-Play User Manual
Part No.: 51301
6 March 2021
(v26)
Document ID: 4686708
Page
|45
OSC
The S-Play can receive OSC through two key methods:
1). Triggers that can be created to start and resume
playlists.
A Trigger will be activated when an
incoming command matches the user
defined Trigger string.
The command must be received upon the
port defined within the settings page
(default 8000).
All OSC commands must start with a
leading '/' sign.
When used in a playlist, the S-PLAY will
wait to receive the Trigger below before
continuing.
2). Integration with the S-Plays OSC API to enable
control of:
Master intensity
Play, pause and stop all playlists
Play, pause and stop individual playlists
Per-playlist intensity control
Visit
www.enttec.com
to download a copy of the OSC
API.
Digital Input
S-Play has 4 Digital input ports to activate triggers.
Idle position for digitals input is high.
A Trigger is registered when the circuit is
completed (low).
When used in a playlist, the S-PLAY will wait to
receive the Trigger below before continuing.
If the input remains on low position while the
timeline goes over the trigger, the playlist
won't pause.
Use Digital inputs with sensors, pressure pads, wall
switches, etc.