Triggers
Use triggers to take control of the timeline of the playlist. When using a trigger, the timeline
will pause until the selected trigger is active.
Triggers can be used to start a playlist or at any point within the timeline.
When a playlist is waiting for a trigger, it will play by either activating the trigger or by pressing
play. This way there is full control of the playback even when the triggers are not available.
When creating new triggers, the ‘Test Trigger’ option can be used to send the trigger being
created.
RS232
RS232 communication settings:
Baud Rate: 9600
Data: 8bits
Parity: none
Stop: 1bit
Flow Control: None
N.B.
Each command string is limited to 1024
Characters.
UDP
UDP communication settings:
A Trigger will be activated when an
incoming UDP command matches the one
defined below.
When used in a playlist, the S-PLAY will
wait to receive the Trigger below before
continuing.
To define a UDP input port navigate to your
S-Play’s Settings page.
UDP strings ending in:
\r
– the
\r
will be
replaced by a carriage return.
\n
–
the
\n
will be replaced by a line feed.