14
IMPORTANT!
READ AND FOLLOW
ALL
INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
Mobile
Home
Installation
The
England’s
Stove
Works,
Inc.
outside
air
kit
MUST
be
used
for
installation
of
this
unit
in
a
mobile
home.
Please
see
the
“Outside
Air”
section
on
page
15
for
more
information
regarding
outside
air
connections.
The
outside
air
inlet
must
be
kept
clear
of
leaves,
ice
and
other
debris.
Keeping
the
outside
air
inlet
free
of
restriction
is
crucial
to
preventing
air
starvation
and
smoke
spillage.
The
pellet
stove
MUST
be
secured
to
the
floor
of
the
mobile
home
using
lag
bolts
and
the
holes
provided
in
the
bottom
of
the
base
for
this
purpose.
Outdoor
‐
aired
space
heaters
must
be
attached
to
the
structure.
The
pellet
stove
MUST
be
grounded
with
#8
solid
copper
grounding
wire
(or
equivalent),
terminated
at
each
end
with
an
NEC
approved
grounded
device.
Carefully
follow
all
clearances
listed
in
the
appropriate
section
of
this
manual
AND
follow
the
venting
manufacturer’s
minimum
clearance
requirements.
Similarly,
be
certain
the
venting
system
used
is
approved
for
mobile
home
use.
Installation
must
be
in
accordance
with
Manufacturers
Home
&
Safety
Standard
(HUD)
CFR
3280,
Part
24
as
well
as
any
applicable
local
codes.
Use
silicone
to
create
an
effective
vapor
barrier
at
the
location
where
the
chimney
or
outside
air
ducting
passes
through
to
the
exterior
of
the
structure.
WARNING:
DO
NOT
INSTALL
IN
A
SLEEPING
ROOM.
CAUTION
THE
STRUCTURAL
INTEGRITY
OF
THE
MANUFACTURED
HOME
FLOOR,
WALL
AND
CEILING/ROOF
MUST
BE
MAINTAINED.
DO
NOT
CUT
THROUGH
FLOOR
JOISTS,
WALL
STUDS,
CEILING
TRUSSES
OR
ANY
OTHER
SUPPORTING
MATERIAL
WHICH
COULD
BE
DETRIMENTAL
TO
THE
STRUCTURAL
INTEGRITY
OF
THE
HOME.
Joist
Shield/Firestop
Mobile
Home
Approved
Type
P
or
PL
Pellet
Vent
Pipe
Roof
Flashing
and
Storm
Collar
Chimney
Cap/Spark
Arrestor
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch (3”) to four-inch (4”).