PROGRAMMING
GUIDE
SOLARDRIVE
PLUS
47
/
107
2.6.1.2. List of Parameters P009 to P033
Parameter
Function
User Level
Default Value
MODBUS
Address
P009
Acceleration Time at Start 1
BASIC
Depending on size
609
P010
Deceleration Time at Stop 1
BASIC
Depending on size
610
P012
Acceleration Time at Start 2
ADVANCED
Depending on size
612
P013
Deceleration Time at Stop 2
ADVANCED
Depending on size
613
P014
Unit of Measure for Ramps 1 and 2
ADVANCED
Depending on size
614
P015
Acceleration Time after Start
ADVANCED
Depending on size
615
P016
Deceleration Time after Start
ADVANCED
Depending on size
616
P018
Start Acceleration Time
ADVANCED
Depending on size
618
P019
End Deceleration Time
ADVANCED
Depending on size
619
P020
Speed Threshold for Initial and Final Ramps
ADVANCED
50.0%
757
P032
Acceleration Ramp in Fire Mode
ENGINEERING
Depending on size
632
P033
Deceleration Ramp in Fire Mode
ENGINEERING
Depending on size
633