PROGRAMMING
GUIDE
SOLARDRIVE
PLUS
27
/
107
2.3.
Manual Mode (Local Mode)
Operation in manual mode allows doing the following:
Manually set the speed of rotation of the connected motor (drive output frequency);
Manually send the START and STOP commands to the motor.
Do the following to set manual mode:
1. Press the emergency pushbutton.
2. Press the LOC/REM key from the display/keypad. The L-CMD LED and the L-REF LED will come on and
the display will show the following:
+
0 . 0 H z
+
0 . 0
A
+
0 . 0 0 r p m
R e f
+ 1 5 0 0 . 0 0 r p m
3. Press
▲
and
▼
;
set the desired speed reference (Ref).
4. Release the emergency pushbutton.
5. Press START to start the motor. The motor will follow the acceleration ramp set in parameter
P009
(see
section 2.6.1).
6. Press STOP to stop the motor. The motor will follow the deceleration ramp set in parameter
P009
(see
section 2.6.1).
When in manual mode, the motor speed may be adjusted by pressing
▲
and
▼
.
Do the following to return to operation in automatic mode:
7. Press the emergency button.
8. Press the LOC/REM key from the display/keypad. The L-CMD LED and the L-REF LED will turn off and
the display will show the following:
I
N V E R T E R
O K
+
0 .
0 0 r p m
+
0 .
0 0 r p m
M E A
P A R
C F [
I
D P ]
9. Release the emergency button.