8.5.2 Blower Cleaning
How often?
Once every 800 to 1,000 hours of operation.
Tools Required:
Screw or 5/16” nut driver, pipe brush, shop vacuum, work gloves, dust mask and safety
glasses.
Personally verify that the main power is turned off and locked out at the circuit
breaker.
Procedure - All Models:
1. Wear all safety equipment.
2. Remove wire guard from the Blower Wheel side (refer to figure).
3. Using a small pipe brush and shop vacuum, gently clean dust from the Blower Wheel
Blades. Be careful not to damage the blades.
4. When finished, reattach the wire guard.
Blower Cleaning
Remove screws
and wire guard.
Gently clean the
blower wheel.
50