
- 9 -
E
nd
u
ra
XL
gr
e
a
s
e
i
n
te
rceptor
s
a
re
ra
te
d
a
nd
s
upplied
wit
h
an
i
n
te
rn
al
fl
o
w
co
n
trol
s
y
s
te
m
a
lr
e
a
dy
i
n
p
lace.
T
hey
d
o
no
t r
equ
ir
e
a
n
ext
e
rna
l flow c
ontr
o
l sy
s
te
m (PDI G-101 listing not available for 150 GPM Models)
or air intake vent unless specified by local code requirements or being operated as a PDI G-101 installation.
E
ndu
ra
X
L
gr
e
as
e
i
n
te
rc
e
ptors
a
re
on
ly t
o
b
e
ins
talle
d
i
n
t
h
e
m
ann
e
r a
nd
f
o
r t
he
a
pplica
tio
n
s
ho
w
n
.
C
on
s
u
lt
l
o
c
a
l
c
o
de
s
f
o
r s
epa
ra
te
tr
a
p
p
in
g
r
e
q
uiremen
ts
,
c
le
a
n
o
u
t loc
a
ti
o
ns
and additional installation instructions.
Full instructional information supplied with every interceptor.
NO
T
ES
:
PROPR
IETARY
AND
CONFIDENTIAL
-
©
C
a
n
pl
a
s 2
0
1
7
4
"
the unit footprin
t
C
o
nc
ret
e
P
a
d
must extend
18" outside
45
.0
0
°
2 1/2"
Min.
18" outside the unit footprin
t
Concr
e
te
Pad
mu
s
t
e
xten
d
8
"
4
"
Top View
R
eb
a
r
Fin
ished
G
ra
d
e
R
eb
a
r
CONCRE
T
E S
L
AB
DE
T
AI
L
F
OR
T
RAF
F
IC
L
OAD
IN
G
(INTERIOR OR EXTERIOR)
Elevation View
(Connec
ting
p
ipe
and
f
it
ti
n
g
s b
y
o
the
rs
)
Fo
r u
n
it d
et
ai
ls
s
ee
s
p
ec
ifi
ca
ti
on
s
h
eet
f
or
selec
ted
un
it
S
IDE
V
IEW
DE
T
A
IL
D
IMENSIO
N
S
26”
22”
14”
34.5”
48.5”
84.5”
50”
72”
Ma
xim
u
m
heigh
t
72”
Ma
xim
u
m
h
e
ig
h
t
78”
48.5”
32”
Native soil
C
o
n
c
re
te
s
la
b
Cr
u
sh
ed
aggregat
e
m
at
e
ri
al
a
pp
ro
xi
ma
tely
3/4"
size
ro
ck
, pe
a gr
ave
l
o
r s
an
d
unit (by others)
Clea
n
o
u
t
to
gr
a
d
e
Flow
on outlet pipe of each
tee
(4
1
4
1
5
5BC
)
2-Way cleanou
t
tee
(414155BC
)
2-Way cleanou
t
mechnical joint
c
oupling
(b
y
o
th
e
rs)
S
tan
d
a
rd
4
”
mechnical joints
c
oupling
(
by
othe
rs
)
S
tanda
rd
4”
on inlet pipe of each
Clean
out
t
o
g
rade
unit (by others)
Flow
Risers
to
g
rade
6
” M
in
. ba
se cr
ush
e
d
agg
regate
m
ater
ia
l
app
ro
x. 3/4" s
ize
ro
ck
,
pea g
rave
l o
r s
an
d
95 p
ro
ct
o
r.
(INTERIOR OR EXTERIOR)
EXCAVA
TI
ON
AND
BACK
FI
L
L
DE
T
AI
L
En
du
ra® X
L -
E
XT
ERIOR
BE
LOW GRADE INS
TAL
LA
TION IN
STRU
CTION
S
B
EL
OW
GRA
DE
IN
ST
AL
LA
TION INSTRU
CTION
S
1.
EX
CA
VA
TIO
N
1.
1
1.
2
W
idth
and
le
ngth
o
f e
xc
ava
tion shall be minimum 12
” g
re
at
er th
an
th
e
ta
nk di
m
en
sio
ns
o
n
al
l side
s.
1.
3
Dept
h
of
e
xc
av
ati
on
sha
ll
be
at least 6
” deeper than tank bot
to
m
.
1.
4
IM
PO
RT
AN
T:
Ma
ximu
m
burial depth 6
ft (72”) measu
red f
ro
m
the
air ba
la
nc
e ch
an
ne
l (
Endu
ra
XL
Logo)
1.
5
Set
the t
an
k
on
w
ell
-p
ac
ked c
rushed agg
reg
at
e
m
at
erial
app
ro
xi
m
at
el
y 3/4
” si
ze
roc
k, pe
a g
ra
ve
l o
r
sa
nd
. W
he
n
setting
End
ur
a®
XL units
th
ey
m
ust
be
le
ve
l l
at
er
al
ly
a
nd
lo
ngit
udin
al
ly.
1.
6
an
cho
ring
m
ay
ho
w
ev
er
be
ne
cessa
ry as de
ter
m
in
ed
by
th
e
speci
fying engi
nee
r. T
ie
-d
ow
n
lo
ca
tio
ns
ar
e
in
co
rpo
ra
ted
to
the
tank
and
can be used in
conjun
ction wit
h
co
at
ed
stain
less
st
ee
l c
ab
le
a
nd
a
n
appli
cable
anch
or
met
hod based on s
ubsoi
l. S
pecific
requi
re
m
en
ts
to
be
de
ter
m
in
ed
b
y speci
fy
in
g
en
gi
nee
r.
2.
B
AC
KFILLING
&
FINI
SH
ED
C
ONCRETE S
LAB
(TRA
FFIC
L
OA
D
R
ATE
D)
AA
SH
TO
304 –
H2
0 (1
6,
000l
bs)
and
app
ro
ved
to C
SA
B48
1.0
Cla
ss
‘S
’ -20˚F
to +100˚F
(-29˚C
to +38˚
C)
2.
1
Pr
ep
ar
ati
on
of
su
b g
ra
de per lo
cal j
urisdi
ctio
na
l r
ec
om
mend
atio
ns
.
2.
2
St
abi
liz
e
and
co
m
pa
ct
sub
g
rade
to 95% p
ro
ct
or per E
xc
av
ati
on
in
form
ati
on
ab
ov
e.
2.
3
.
2.
4
ade
le
ve
l.
2.
5
2.
6
Pl
ac
e
minim
um
6”
agg
reg
at
e base bene
at
h po
ur
ed
st
ru
ct
ur
al
sl
ab
. A
gg
reg
at
e sh
ou
ld
be
3/
4”
si
ze
ro
ck
or
pea
sh
ingl
e.
2.
7
re
fer
to
lo
ca
l speci
fy
ing
engineer
re
commend
ations and/
or
lo
ca
l c
ode
req
ui
re
m
en
ts
. N
ot
e:
C
on
cr
et
e sl
ab
dime
nsio
ns s
ho
wn
a
re
fo
r i
llust
ra
tion purposes onl
y.
2.
8
Co
nc
re
te
to
be
28
d
ay
com
pr
essi
ve st
rengt
h
to 4000 PSI.
Rein
fo
rc
em
en
t wit
h
No
.4
rebar (1/2”)
g
rade
6
0
st
ee
l per
A
ST
M
A6
15:
con
ne
ct
ed with tie wi
re
. Rebar
to
be
2½
” f
ro
m
edge
of
co
nc
re
te
. Reb
ar
spaci
ng
12
” gri
d.
4”
spacing
a
ro
un
d
acc
ess ope
ni
ng
s.
3.
PIPING
CONN
EC
TION
S
3.
1
Al
l E
ndu
ra
®
XL
G
rease
In
te
rc
ep
tors a
re
ma
nu
fa
ct
ur
ed with
no
h
ub
co
nne
ction
s.
Th
readed
con
ne
ctio
ns
a
re
3.
2
Lo
call
y app
ro
ved
mec
hani
cal joi
nt (MJ)
couplings a
re used
to
co
nn
ec
t t
he
in
let
a
nd
o
ut
let pipi
ng
to
th
e
3.
3
Ma
ke
sys
tem
pipi
ng
con
ne
ctions usi
ng
lo
cally app
ro
ved
M
J c
ouplings
in
sta
lling
to
m
an
uf
ac
tu
re
r’s
bel
ow
the
wa
ter
le
ve
l.
DO N
OT
PRE
SSURE
TEST –
R
isk of serious Inju
ry or De
ath
.
3.
4
DO
N
OT
dec
rease pipe diame
ter ac
ross the unit (i.
e. 4 inc
h in
le
t,
3
in
ch
o
utlet).
If
the pipi
ng
sy
st
em
in
st
all
ed in
com
pli
an
ce
w
ith
lo
cal
cod
e.
4
EX
TE
N
SION
RI
SE
RS
(O
ptional
)
4.
1
En
du
ra
®
XL
E
xt
ensi
on
Risers p
ro
vide
a
m
axim
um
o
f 3
5”
e
xt
en
sio
n per rise
r.
B
ased
on
m
axim
um
in
st
all
ati
on
depth
up
to
a
m
aximum of 72
” depth of buri
al
ca
n
ac
hie
ved
(see
1.
4
ab
ov
e),
addi
ng
Ex
te
nsio
n
Risers
(or
pa
rt
the
reo
f) d
uring inst
al
la
tio
n.
R
isers
ar
e
cu
t t
o
lengt
h
on
si
te
to
su
it inst
al
la
tio
n.
4.
2
4.
3
4.
4
m
ec
ha
nism.
C
ut
a
nd
e
xt
en
d a length of 1½
” D
WV pipe per inst
ru
cti
ons supp
lie
d.
4.
5
cle
anly
b
y h
and or
mec
hani
cal means using guide rings
m
ol
ded
in
to
th
e
riser
to
gi
ve clea
n st
raig
ht
cu
t.
4.
6
Fit
riser
se
al
p
ro
vided
ov
er the
cut edge
o
f the riser
and
lo
ca
te
fra
me (s
upplied)
o
ver the se
al
m
ak
in
g
su
re
it is
fu
lly se
at
ed
. S
ec
ur
e
w
ith lag sc
re
w
s p
ro
vided
using the p
re
-dril
led
lo
ca
tio
ns in
fr
am
e.
4.
7
Repe
at p
ro
cess
fo
r additi
ona
l riser if/as
requi
re
d.
4.
8
DWV
and
se
cu
re t
he s
upp
or
t t
o the
fr
am
e
wit
h the sc
re
w
p
ro
vide
d.
So
lv
en
t w
el
d
a
1½
” v
en
t t
ee
on
to
p
of
th
e
pipe
to
a
ct
as
a
h
an
dl
e.
4.
9
D
ATE
:
JAN, 2020
R
E
V:
1
.3
M
A
T
L
:
P
E
D
ESCRIPT
ION
:
D
W
G
B
Y
: L
.S
.
DW
G
NU
M
BER
: XL100BGT
C
an
p
las
I
nd
ustrie
s
Ltd
.
500
V
e
ter
ans
D
ri
ve, Bo
x 1800
B
a
rr
ie
, Ont
ari
o
,
Canada L4M 4V3
CAN: 1-800-461-1771 USA: 1-888-461-5307
Endura brand produc
ts
75 GPM AND 100 GPM MODELS
manufac
tur
ed b
y
Ca
np
la
s I
ndus
tr
ies
Lt
d.
40
1
00
A
04
4
0
100
A
04
M
40
10
0A0
4
T 4
0
10
0
A
04
M
T
40
1
50
A
04
4
0
150
A
04
M
40
15
0A0
4
T 4
0
15
0
A
04
M
T
*
*
*