Endura 40100A04 Installation Operation & Maintenance Download Page 2

- 2 -

GR

EA

SE

 IN

TE

RC

EP

TO

R

GR

EA

SE

 IN

TE

RC

EP

TO

R

GR

EA

SE

 IN

TE

RC

EP

TO

R

GR

EA

SE

 IN

TE

RC

EP

TO

R

MANUAL

LIFTING 

POINTS

FACTORY PLUMBED 

3-WAY OUTLET 

SYSTEM

REMOTE PUMP READY

AIR & WATER TIGHT 

EXTENSION SYSTEM

INTEGRATED LIFTING 

LOCATIONS

CLOSED RIBS FOR 

FLOTATION RESISTANCE

INTEGRATED TIE DOWN 

LOCATIONS

CORRUGATED WALLS 

FOR STRENGTH

LOAD RATED 

COVER & FRAME

CUT TO SUIT RISER 

EXTENSION

BUILT-IN HEIGHT 

ADJUSTMENT

AIR BALANCED

ENVIRONMENT

TANK PROFILE 

RESISTS 

FLOTATION

Features Overview

About Your Purchase:

The Endura® XL grease interceptor and it associated products are the latest addition to the proven line of Endura® 
Grease Management products. 

We have spent many thousands of hours in the development of Endura® XL, our aim being simple – to produce 
the industry’s best Hydromechanical Grease Interceptor.

From the ground up, Endura® XL has been ‘Engineered for Easy’. Working with distributors, installers, engineers, 

the feedback gained and rolled it into one comprehensively designed solution to meet as broad a range of these 
requirements as possible. 

Endura® XL is the most widely evaluated and approved hydromechanical interceptor in the current marketplace, 
being successfully tested by independent third parties to meet all requirements of PDI G-101*, ASME A112.14.3 
(Type A* & C) / NSF ES15741* and CSA B481.1. 

*

PDI G-101, ASME A112.14.3 TYPE A, AND NSF ES 15741 APPLICABLE TO 75 AND 100 GPM MODELS ONLY

Summary of Contents for 40100A04

Page 1: ...appurtenance your Endura grease interceptor MUST be isolated from the drainage system in the event that nal drain testing or other system pressure testing is required DO NOT under any circumstances s...

Page 2: ...latest addition to the proven line of Endura Grease Management products We have spent many thousands of hours in the development of Endura XL our aim being simple to produce the industry s best Hydrom...

Page 3: ...heck review building plumbing pretreatment sewer and waste water Bottom line those who enforce the rules and regulations Cost Index A way of indicating the relative cost of different types of intercep...

Page 4: ...mum safety factor of 2 shall be applied in calculation design Concrete Anchor Base if anchoring is required Min 6 Inle O t utlet Min 12 Min 12 Min 8 6 Minimum Base of Crushed aggregate material approx...

Page 5: ...Extension Installation Guide 8 Finish to grade floor For in ground applications with vehicular traffic the upper 8 requires a reinforced concrete slab Refer to the Installation Specification section o...

Page 6: ...150 gpm tank 4 Spigot connections with S Rated Lids 1 40150A04 Endura XL 150 gpm tank 4 Spigot connections with M Rated Lids 1 40150A04M Endura XL 150 gpm tank 4 Threaded connections with S Rated Lid...

Page 7: ...hall additionally operate with an air balanced environment to equalize variation in internal pressures being controlled and maintained with an appropriately sized air balance means be supported by a L...

Page 8: ...ongitudinally 1 6 anchoring may however be necessary as determined by the specifying engineer Tie down locations are incorporated to the tank and can be used in conjunction with coated stainless steel...

Page 9: ...y specifying engineer 2 BACKFILLING FINISHED CONCRETE SLAB TRAFFIC LOAD RATED AASHTO 304 H20 16 000lbs and approved to CSA B481 0 Class S 20 F to 100 F 29 C to 38 C 2 1 Preparation of sub grade per lo...

Page 10: ...ol If Required External Flow Control If Required GR N I E S A E R E T C P E T R O GR N I E S A E E T RC P E T R O GREA N I E S R E T C P E T R O GR N I E S A E R E T C P E T R O Endura XL grease inter...

Page 11: ...criterial are met See Page 12 Trapping equivalent in compliance with applicable plumbing code requirements Venting The installation of the interceptor shall be vented downstream in accordance with lo...

Page 12: ...main drain line connected to the interceptor The remain accessible for maintenance and The location of the cleanout should be recorded in you Installer Hand Over Check List See Page 14 is important th...

Page 13: ...enetration tank seal Part 40100 TPS into the opening prepared and lubricate well using silicone pipe lubricant 6 As the orientation of the pipe when installed is important mark or identify on the top...

Page 14: ..._______ Connections Cleanouts Mark where installed Extension Risers added Yes if Yes approx length of riser installed _________in m No Flow Control Handle Extended Yes No See Riser Extension Instructi...

Page 15: ...place and well tightened MissingboltsMUSTbereportedtomanagementandreplacedimmediately Covers MUST meet the required load rating for the application see the Technical Information section Do NOT use alt...

Page 16: ...ght sampling air balance cap must be raised also Air Balance Hole Maintenance IMPORTANT Regular Removal of Fat Oil and Grease Due to the capacity of your Endura XL Grease Interceptor it is necessary t...

Page 17: ...of damage to the internal flow control where fitted by rooting or other equipment Access to the Outlet Well Although essentially a closed area the outlet system is able to be accessed by removal of th...

Page 18: ...olume of Waste Removed _____________________ Gallons Liters Inlet Baffle Opened Inspected Yes No Flow Control Checked Cleaned Yes No Note The flow control device internal or external shall be inspecte...

Page 19: ...equency I think I have missing parts Parts have been removed or lost during prior servicing Check exploded drawing in this manual to confirm the parts that are supposed to make up your interceptor mod...

Page 20: ...Load Drainage Period 70 84 1 min 70 84 l p m 70 84 2 min 35 42 l p m 5 Select Interceptor falls between two sizes select the larger of the two interceptors For a one minute drainage period For a two m...

Page 21: ...ivalent is not directly achievable by application of a standard formula As an experienced manufacturer in the Grease Management market we have been able to identify and validate a a manufacturers reco...

Page 22: ...nce will be proportionally less too Rates will vary significantly by region and by contractor Always use a licensed or approved contractor to maintain your interceptor Do Endura XL tanks need to be di...

Page 23: ...th the Products or on Manufacturer s website ii the Products have been installed and used in strict compliance with Manufacturer s written instructions as published and updated from time to time by Ma...

Page 24: ...Email us feedback endurainterceptor com Limited LifetimeWarranty Registration Card Congratulations on your purchase of the Endura XL Grease Interceptor This product is supplied with a the manufacturer...

Reviews: