Endura 40100A04 Installation Operation & Maintenance Download Page 7

Endura XL150

40150A04

40150A04M

150  (9.5)

96.3%

160˚F 

(71˚C)

S

 10,000 lb (4536 kg)

M

 2000 lb (907 kg)

S

 20,000 lb (9072 kg)

M

 4000 lb (1814 kg)

283 lb 

(128  kg)

257 gal 

(973 L)

4”

300  (136)

1097 (498)

Technical Information

- 7 -

Contractor shall install a Endura® XL Hydromechanical Grease Interceptor (HGI), Part No.

40100A04 

40100A04M  

40150A04 

  40150A04M  

,  4075A04 

  , 4075A04M 

 (See page 6 table), and rated to

100GPM 

150GPM 

  75GPM 

   (Indicate as Applicable) independently

❑ 

(Tick if required).

72” regardless of the application and when requiring Riser Extension, the installing contractor will extend the opening device according 

* PDI G-101 AND NSF ES 15741 APPLICABLE TO 75 AND 100 GPM MODELS ONLY.

*

to manufacturers published instructions. The outlet system will provide facility for connections to be made perpendicular to the inlet 

shall provide mechanical joint connectors or requisite materials to connect the grease interceptor to the drainage system, additionally 
making adequate provision for management of food debris and solids.
Interceptor shall be furnished with two (2) access covers, maximizing internal visibility for inspection and maintenance when removed. 
These covers shall be capable of withstanding a proof load of 20,000lbs, approved for application at temperatures fr

om -20˚F to +100˚F 

(-29˚C to +38˚C) and will be mechanically secured when operational. 
The interceptor tank shall be constructed with seemless engineered thermoplastics, evaluated and approved to the material performance 
requirements of CSA B481.0
The interceptor shall additionally; operate with an air-balanced environment to equalize variation in internal pressures being controlled 
and maintained with an appropriately sized air balance means; be supported by a Lifetime Warranty against manufacturing defect.

  , 4044275A 

    

40442100AT 

   , 4044275AT 

the interceptor, being vented and installed according to manufactures instructions and the currently published version of PDI G-101. 
Interceptor will be located within 25ft developed pipe run of the last connected appliance for standard compliance. Where applicable 

discharge appliances and the interceptor inlet. 

Air Intake can be connected to building 
vent system or be independently to the 
atmosphere based on local code.

• Flow Control

• Flow Control

Pipe by 

others

• Air Intake Tee

• Air Intake Tee

Connection

Iron Pipe Size 

(Solvent weld)

4” h x h

A

6.13”

(155.7mm)

B

6.84”

(173.7mm)

C

-

4” h x h

3.19”

(81mm)

5.04”

(128mm)

2.72”

(69.1mm)

Capacities

External 
Flow Control 
Dimensions

For full CAD, BIM Models 
and 3 Part Master Format 
Specs visit www.arcat.com
Search keyword “endura”

CAD                BIM             SPECS

®

Endura XL75

Endura XL100

• Part Number

4075A04

4075A04M

40100A04

40100A04M

US Gallons Per Minute  - GPM 

(L/Sec)

75  (4.74)

100  (6.3)

A112.14.3)

>98%

>98%

Operating Temperature Capabilities

160˚F 

(71˚C)

160˚F 

(71˚C)

Cover Load Rating- CSA B481.0

S

 10,000 lb (4536 kg)

M

 2000 lb (907 kg)

S

 10,000 lb (4536 kg)

M

 2000 lb (907 kg)

CSA B481.0

Min. Test Load for Approval

S

 20,000 lb (9072 kg)

M

 4000 lb (1814 kg)

S

 20,000 lb (9072 kg)

M

 4000 lb (1814 kg)

Unit Weight (Empty) 

233 lb 

(106  kg)

283 lb 

(128  kg)

Liquid Capacity

158 gal 

(598 L)

257 gal 

(973 L)

Connection size 

(mechanical joint only)

4”

4”

Min. Grease Capacity - lb 

(kg)

150  (68.2)

200  (90.8)

Grease Capacity Actual 

(ASME A112.14.3) - lb 

(kg)

† 

NSF ES 15741

559 (253)

1058 (480)

Summary of Contents for 40100A04

Page 1: ...appurtenance your Endura grease interceptor MUST be isolated from the drainage system in the event that nal drain testing or other system pressure testing is required DO NOT under any circumstances s...

Page 2: ...latest addition to the proven line of Endura Grease Management products We have spent many thousands of hours in the development of Endura XL our aim being simple to produce the industry s best Hydrom...

Page 3: ...heck review building plumbing pretreatment sewer and waste water Bottom line those who enforce the rules and regulations Cost Index A way of indicating the relative cost of different types of intercep...

Page 4: ...mum safety factor of 2 shall be applied in calculation design Concrete Anchor Base if anchoring is required Min 6 Inle O t utlet Min 12 Min 12 Min 8 6 Minimum Base of Crushed aggregate material approx...

Page 5: ...Extension Installation Guide 8 Finish to grade floor For in ground applications with vehicular traffic the upper 8 requires a reinforced concrete slab Refer to the Installation Specification section o...

Page 6: ...150 gpm tank 4 Spigot connections with S Rated Lids 1 40150A04 Endura XL 150 gpm tank 4 Spigot connections with M Rated Lids 1 40150A04M Endura XL 150 gpm tank 4 Threaded connections with S Rated Lid...

Page 7: ...hall additionally operate with an air balanced environment to equalize variation in internal pressures being controlled and maintained with an appropriately sized air balance means be supported by a L...

Page 8: ...ongitudinally 1 6 anchoring may however be necessary as determined by the specifying engineer Tie down locations are incorporated to the tank and can be used in conjunction with coated stainless steel...

Page 9: ...y specifying engineer 2 BACKFILLING FINISHED CONCRETE SLAB TRAFFIC LOAD RATED AASHTO 304 H20 16 000lbs and approved to CSA B481 0 Class S 20 F to 100 F 29 C to 38 C 2 1 Preparation of sub grade per lo...

Page 10: ...ol If Required External Flow Control If Required GR N I E S A E R E T C P E T R O GR N I E S A E E T RC P E T R O GREA N I E S R E T C P E T R O GR N I E S A E R E T C P E T R O Endura XL grease inter...

Page 11: ...criterial are met See Page 12 Trapping equivalent in compliance with applicable plumbing code requirements Venting The installation of the interceptor shall be vented downstream in accordance with lo...

Page 12: ...main drain line connected to the interceptor The remain accessible for maintenance and The location of the cleanout should be recorded in you Installer Hand Over Check List See Page 14 is important th...

Page 13: ...enetration tank seal Part 40100 TPS into the opening prepared and lubricate well using silicone pipe lubricant 6 As the orientation of the pipe when installed is important mark or identify on the top...

Page 14: ..._______ Connections Cleanouts Mark where installed Extension Risers added Yes if Yes approx length of riser installed _________in m No Flow Control Handle Extended Yes No See Riser Extension Instructi...

Page 15: ...place and well tightened MissingboltsMUSTbereportedtomanagementandreplacedimmediately Covers MUST meet the required load rating for the application see the Technical Information section Do NOT use alt...

Page 16: ...ght sampling air balance cap must be raised also Air Balance Hole Maintenance IMPORTANT Regular Removal of Fat Oil and Grease Due to the capacity of your Endura XL Grease Interceptor it is necessary t...

Page 17: ...of damage to the internal flow control where fitted by rooting or other equipment Access to the Outlet Well Although essentially a closed area the outlet system is able to be accessed by removal of th...

Page 18: ...olume of Waste Removed _____________________ Gallons Liters Inlet Baffle Opened Inspected Yes No Flow Control Checked Cleaned Yes No Note The flow control device internal or external shall be inspecte...

Page 19: ...equency I think I have missing parts Parts have been removed or lost during prior servicing Check exploded drawing in this manual to confirm the parts that are supposed to make up your interceptor mod...

Page 20: ...Load Drainage Period 70 84 1 min 70 84 l p m 70 84 2 min 35 42 l p m 5 Select Interceptor falls between two sizes select the larger of the two interceptors For a one minute drainage period For a two m...

Page 21: ...ivalent is not directly achievable by application of a standard formula As an experienced manufacturer in the Grease Management market we have been able to identify and validate a a manufacturers reco...

Page 22: ...nce will be proportionally less too Rates will vary significantly by region and by contractor Always use a licensed or approved contractor to maintain your interceptor Do Endura XL tanks need to be di...

Page 23: ...th the Products or on Manufacturer s website ii the Products have been installed and used in strict compliance with Manufacturer s written instructions as published and updated from time to time by Ma...

Page 24: ...Email us feedback endurainterceptor com Limited LifetimeWarranty Registration Card Congratulations on your purchase of the Endura XL Grease Interceptor This product is supplied with a the manufacturer...

Reviews: