Operation / Maintenance
- 16 -
Ensure that any operatives or employees that attend to the
grease interceptor are adequately protected. As a minimum
it is recommended that protective gloves, eyewear and a
mask are provided and used.
Where a third party contractor or service is responsible
for the regular maintenance of the interceptor (strongly
recommended) it is their responsibility not only to ensure
that their own protective practices and procedures are
maintained and followed, but that they also protect those
with access to the vicinity of the interceptor when it is
Air Balanced Operation:
Endura® XL is designed to function based on a balance air environment.
During the maintenance of your interceptor, it is important to check
that the breather hole in the outlet vent (see diagram) is unobstructed.
The smallest restriction can drastically impact the performance of your
interceptor and can cause the accumulated contents of the interceptor
to be discharged to the downstream drain system particularly if
access/breather cap must be relocated upward as close as possible to
the underside of the cover to maintain its function.
IF YOU DO NOT SEE A GREY CAP ON TOP
OF THE OUTLET SYSTEM, CONTACT YOUR
INSTALLER/MAINTENANCE CONTRACTOR
IMMEDIATELY AND IF NECESSARY
PURCHASE A REPLACEMENT.
Air Balance/
Sampling Cap is
ESSENTIAL to the
operation of the
interceptor and
must be kept free
of debris.
If extending height,
sampling/air balance
cap must be raised also.
Air Balance Hole
Maintenance
IMPORTANT:
Regular Removal of Fat, Oil and Grease:
Due to the capacity of your Endura® XL Grease Interceptor it is necessary to have a licensed and locally approved service
provider manage the regular removal, cleaning and disposal of the Fats, Oil and Grease that is captured in your interceptor.
rule of thumb your interceptor should be cleaned every 8-12 weeks. You should anticipate a minimum of 4-6 cleans per year.
BMP
BMP
undergoing maintenance. In addition they will be stewards
to premises management issues with for example, but not
limited to, interceptor operation, damages, spills, etc.
IMPORTANT:
maintenance (See Maintenance Procedures – Pg 17). You
should consider your facility to be in partnership with the
management that is mandated to protect your business,
your community and the environment.
Regular Removal of Fat, Oil and Grease:
Due to the capacity of your Endura® XL Grease Interceptor
it is necessary to have a licensed and locally approved
service provider manage the regular removal, cleaning and
disposal of the Fats, Oil and Grease that is captured in your
interceptor.
WARNING – SAFETY FIRST!
GREASE INTERCEPTORS ARE HAZARDOUS
ENVIRONMENTS AND MUST NEVER BE LEFT UNCOVERED
AND UNATTENDED, EVEN DURING MAINTENANCE.
• All access covers MUST be fully and completely secured
• All required bolts MUST at all times be in place and well tightened
• Missing bolts MUST be reported to management and replaced immediately
•
•
Covers MUST meet the required load rating for the application (see the
Technical Information section)
Do NOT use alternate covers.