Proline Promass O 100 HART
System integration
Hauser
43
9
System integration
9.1
Overview of device description files
9.1.1
Current version data for the device
Firmware version
01.01.zz
• On the title page of the Operating instructions
• On transmitter nameplate (→ 13)
• Parameter
firmware version
Diagnostics → Device info → Firmware version
Release date of firmware version
06.2014
---
Manufacturer ID
0x11
Manufacturer ID
parameter
Diagnostics → Device info→ Manufacturer ID
Device type ID
0x4A
Device type
parameter
Diagnostics → Device info → Device type
HART protocol revision
7
---
Device revision
2
• On transmitter nameplate (→ 13)
•
Device revision
parameter
Diagnostics → Device info → Device revision
9.1.2
Operating tools
The suitable device description file for the individual operating tools is listed in the table
below, along with information on where the file can be acquired.
Operating tool via HART protocol Sources for obtaining device descriptions
• Field Xpert SFX350
• Field Xpert SFX370
Use update function of handheld terminal
FieldCare
•
→ Download Area
• CD–ROM (contact Hauser)
• DVD (contact Hauser)
AMS Device Manager
(Emerson Process Management)
→ Download Area
SIMATIC PDM
(Siemens)
→ Download Area
Field Communicator 475
(Emerson Process Management)
Use update function of handheld terminal
9.2
Measured variables via HART protocol
The following measured variables (HART device variables) are assigned to the dynamic
variables at the factory:
Dynamic variables
Measured variables
(HART device variables)
Primary dynamic variable (PV)
Mass flow
Secondary dynamic variable (SV)
Totalizer 1
Tertiary dynamic variable (TV)
Density
Quaternary dynamic variable (QV)
Temperature
Summary of Contents for Proline Promass O 100HART