System integration
Proline Promass O 100 HART
44
Hauser
The assignment of the measured variables to the dynamic variables can be modified and
assigned as desired via local operation and the operating tool using the following
parameters:
• Expert → Communication → HART output → Assign PV
• Expert → Communication → HART output → Assign SV
• Expert → Communication → HART output → Assign TV
• Expert → Communication → HART output → Assign QV
The following measured variables can be assigned to the dynamic variables:
Measured variables for PV (primary dynamic variable)
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary dynamic
variable)
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
The range of options increases if the measuring device has one or more application
packages.
Heartbeat Technology Application Package
Additional measured variables are available with the Heartbeat Technology application
package:
• Carrier pipe temperature
• Oscillation amplitude
Device variables
The device variables are permanently assigned. A maximum of 8 device variables can be
transmitted:
• 0 = mass flow
• 1 = volume flow
• 2 = corrected volume flow
• 3 = density
• 4 = reference density
• 5 = temperature
• 6 = totalizer 1
• 7 = totalizer 2
• 8 = totalizer 3
• 9 = dynamic viscosity
• 10 = kinematic viscosity
• 11 = temp. compensated dynamic viscosity
• 12 = temp. compensated kinematic viscosity
• 13 = target mass flow
• 14 = carrier mass flow
• 15 = concentration
Summary of Contents for Proline Promass O 100HART