Proline Cubemass C 300
Diagnostics and troubleshooting
Hauser
159
Diagnostic
number
Short text
Remedy instructions
Status
signal
[from the
factory]
Diagnostic
behavior
[from the
factory]
119
Sensor initialization
active
Sensor initialization in progress, please
wait
C
Warning
140
Sensor signal
asymmetrical
1. If available: Check connection cable
between sensor and transmitter
2. Check or replace sensor electronic
module (ISEM)
3. Replace sensor
S
Alarm
141
Zero adjustment failed
1. Check process conditions
2. Repeat commissioning procedure
3. Check sensor
F
Alarm
142
Sensor index coil
asymmetry too high
Check sensor
S
Warning
144
Measurement error too
high
1. Check process conditions
2. Check or change sensor
F
Alarm
Diagnostic of electronic
201
Electronics faulty
1. Restart device
2. Replace electronics
F
Alarm
242
Firmware incompatible
1. Check firmware version
2. Flash or replace electronic module
F
Alarm
252
Module incompatible
1. Check electronic modules
2. Check if correct modules are
available (e.g. NEx, Ex)
3. Replace electronic modules
F
Alarm
262
Module connection
interrupted
1. Check or replace connection cable
between sensor electronic module
(ISEM) and main electronics
2. Check or replace ISEM or main
electronics
F
Alarm
270
Main electronics
defective
1. Restart device
2. Replace main electronic module
F
Alarm
271
Main electronics faulty
1. Restart device
2. Replace main electronic module
F
Alarm
272
Main electronics faulty
Restart device
F
Alarm
273
Main electronics
defective
1. Pay attention to display emergency
operation
2. Replace main electronics
F
Alarm
275
I/O module defective
Change I/O module
F
Alarm
276
I/O module faulty
1. Restart device
2. Change I/O module
F
Alarm
283
Memory content
inconsistent
Restart device
F
Alarm
302
Device verification active Device verification active, please wait.
C
Warning
303
I/O 1 to n configuration
changed
1. Apply I/O module configuration
(parameter 'Apply I/O configuration')
2. Afterwards reload device description
and check wiring
M
Warning
304
Device verification failed 1. Check verification report
2. Repeat commissioning procedure
3. Check sensor
F
Alarm
311
Sensor electronics
(ISEM) faulty
Maintenance required!
Do not reset device
M
Warning
330
Flash file invalid
1. Update firmware of device
2. Restart device
M
Warning
Summary of Contents for Proline Cubemass C 300