Operation
Proline Cubemass C 300
134
Hauser
11.4.1 "Measured variables" submenu
The
Measured variables
submenu contains all the parameters needed to display the
current measured values for each process variable.
Navigation
"Diagnostics" menu → Measured values → Measured variables
‣
Measured variables
Mass flow
Volume flow
Corrected volume flow
Density
Reference density
Temperature
Pressure
Concentration
Target mass flow
Carrier mass flow
Target corrected volume flow
Carrier corrected volume flow
Target volume flow
Carrier volume flow
Parameter overview with brief description
Parameter
Prerequisite
Description
User interface
Mass flow
–
Displays the mass flow that is currently
measured.
Dependency
The unit is taken from:
Mass flow unit
Signed floating-point
number
Volume flow
–
Displays the volume flow that is
currently calculated.
Dependency
The unit is taken from the
Volume flow
unit
Signed floating-point
number