Accessories
8.1
Sensors
• Orbisint CPS11/CPS11D
pH electrode for process applications, with PTFE diaphragm, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI028/C07/en)
• Orbisint CPS12/CPS12D
ORP electrode for process applications, with PTFE diaphragm, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI367/C07/en)
• Ceraliquid CPS41/CPS41D
pH electrode with ceramics diaphragm and KCl liquid electrolyte, Memosens technology as
option;
Ordering acc. to product structure, see Technical Information (TI079/C07/en)
• Ceraliquid CPS42/CPS42D
ORP electrode with ceramics diaphragm and KCl liquid electrolyte, Memosens technology as
option;
Ordering acc. to product structure, see Technical Information (TI079/C07/en)
• Ceragel CPS71/CPS71D
pH electrode with double chamber reference system and integrated bridge electrolyte,
Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI245/C07/en)
• Ceragel CPS72/CPS72D
ORP electrode with double chamber reference system and integrated bridge electrolyte,
Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI374/C07/en)
• Orbipore CPS91/CPS91D
pH electrode with open aperture for media with high dirt load, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI375C/07/en)
• Tophit CPS471
Sterilisable and autoclavable ISFET sensor for food and pharmaceuticals, process technology,
water treatment and biotechnology;
Ordering acc. to product structure, see Technical Information (TI283/C07/en)
• Tophit CPS441
Sterilisable ISFET sensor for media with low conductivity, with liquid KCl electrolyte;
Ordering acc. to product structure, see Technical Information (TI352/C07/en)
• Tophit CPS491
ISFET sensor with open aperture for media with high dirt load;
Ordering acc. to product structure, see Technical Information (TI377/C07/en)
8.2
Connection accessories
• Special measuring cable CPK9
For pH/redox electrodes with TOP68 plug-in head
Order as per product structure, see Technical Information (TI 118C/07/en)
• Special measuring cable CPK1
For pH/redox electrodes with GSA plug-in head
Order as per product structure, see Technical Information (TI 118C/07/en)
• Special measuring cable CPK2
For pH/redox electrodes with GSA plug-in head, with three electrode connectors
Order as per product structure, see Technical Information (TI118C/07/en)
• Special measuring cable CPK12
For pH glass electrodes and ISFET sensors with TOP68 plug-in head
Order as per product structure, see Technical Information (TI 118C/07/en)