Liquisys M CPM223/253
Installation
Hauser
13
Transmitter post mounting
!
Note!
You require a post mounting kit to secure the field device to horizontal and vertical posts or pipes
(max. Ø 60 mm(2.36")). This can be acquired as an accessory (see "Accessories" section).
C07-CxM253xx-11-06-00-en-003.eps
Fig. 8:
Post mounting field device to cylindrical pipes
For post mounting the transmitter, proceed as follows:
1.
Guide the two securing screws (1) of the mounting kit through the openings of the securing
plate (3).
2.
Screw the securing plate onto the transmitter using the four fixing screws (2).
3.
Secure the retainer with the field device using the clip on the post or pipe.
1
2
3
1
1
3
Ø
max.
60
/
2.36