Appendix
Liquisys M CCM223/253
114
Hauser
Operating matrix - version EP
a0002637-en
C
A1
A4
A3
A5
A6
A
B
Z
Z4
O332
B5
Z5
O333
B1
Z1
B2*
Z2
O3(3)
B3
Z3
O331
B4
O3(2)
O321
O
O1
O2
O3(1)
O311
O312
O313
C35
C25
C15
C26
C32
C22
C12
C33
C23
C13
C34
C24
C14
C31
C21
C11
Z6
A2
C15
C14
C15
CURRENT INPUT
SETUP 2
SETUP 1
CURRENT OUTPUT
Enter value of ORP
buffer
0 ... 1500 mV
Buffer value of last cal.
Meas. value display
ORP (dep. on B1)
pH;
1st error is displayed
(if present)
Meas. value display
Temperature display in °F
Meas. value display
pH signal in mV
Other errors are
displayed
(up to max. 10 errors)
Meas. value display
No temp. display
Enter pH value
of first buffer solution
pH 3.50 ... 9.50
Buffer value of last cal.
Controller switch-off
by sample stream
INS
Off;
Controller switch-off
by current input
Input
Off;
Select meas. parameter
for 2nd current output
pH; ORPmV; Contr
°C;
Select current range
0–20 mA
4–20 mA;
lin = linear
pH compensation
Manu; Auto
Off;
Enter pH value
of second buffer solution
pH 3.50 ... 9.50
Buffer value of last cal.
Slope is
displayed
38.00 ... 65.00 mV/pH
59.16 mV/pH
Switch-off direction
for current input
High
Low;
Zero calibration
yes
(only if A1 = 963)
no;
Enter calibration
temperature
–10 ... +60 °C
25.0 °C
Select sensor
140;
141; 240; 241;
963; 120
Select current output
Output2
Output1;
Select operating mode
pH; ORP mV
Off;
Enter DPD
calibration value
Value of last cal.
Calibrating
Adopt if stable
±1 mV (> 10 s)
Calibrating
Adopt if stable
pH ±0.05 (> 10 s)
Delay for contr.
sw.-off by sample stream
0 ... 2000 s
0 s
Delay for controller
sw.-off current input
0 ... 2000 s
0 s
Tab = Table
sim = simulation
Manual
pH compensation
pH 4.00 ... 9.00
last comp. value
Delay for contr.
sw.-on by sample stream
0 ... 2000 s
0 s
Delay for controller
sw.-on current input
0 ... 2000 s
0 s
Enter simulation
value
0 ... 22.0 mA
current value
Select table
options
edit
read
Enter number of
table pairs
1 ... 10
1
Select table
pairs
1 ... No. of table pairs
asign
1
Enter correct
process temperature
0 ... 50 °C
current meas. value
Calibrating
Adopt if stable
pH ±0.05 (> 10 s)
Select
digital input 1
Clean Trig.
ext.Hold
Switch-off limit
for current input
0 ... 100%
50%
Enter temperature
difference (offset)
–5.0 ... + 5.0 °C
current offset
Calibration status is
displayed
Exxx
o.k.
Calibration status is
displayed
Exxx
o.k.
Enter calibration
results
no; new
yes;
Store calibration
result
no; new
yes;
Zero point is
displayed
–100 ... +100 mV
Slope is
displayed
min. 25% (3%)
max. 500%
100%
CALIBRATION
ORP mV
(dep. on B1)
CALIBRATION
pH
(dep. on B1)
MEAS. VALUE
DISPLAY
TEMPERATURE
DISPLAY
with
in °C
CALIBRATION
Cl2 / ClO2
Feedforward control
to PID controller
lin = linear
Off;
Meas. value display
Sensor current in nA
Edit:
Code
22
Read:
any
code
Edit:
Code
22
Read:
any
code
Display unit
ppm; ppb
mg/l;
Enter 0/4-mA value
0.00 mg/l;
0.00 ppm
0 ppb;
pH 4.00;
0 mV;
0 °C;
0 ... 20 (5) mg/l
; 0 … 20 ppm
0 … 20000 ppb
pH 4 ... 9
0 ... 1500 mV
0 ... 50 °C
Enter 20-mA value
2.0 (0.5);
2.0 ppm;
2000 ppb;
pH 9.00;
1000 mV;
50 °C;
0 ... 20 (5) mg/l
0 … 20 ppm
0 … 20000 ppb
pH 4 ... 9
0 ... 1500 mV
0 ... 50 °C
* field B2 not available for CCS240/241
CALIBRATION
zero
(CCS120)
Zero calibration
yes
(only if A1 = 120)
no;
Calibration status is
displayed
Exxx
o.k.
Store calibration
result
no; new
yes;
Summary of Contents for Liquisys M CCM223
Page 109: ...Liquisys M CCM223 253 Technical data Endress Hauser 109...
Page 116: ...Appendix Liquisys M CCM223 253 116 Endress Hauser a0002639 en...
Page 120: ...Appendix Liquisys M CCM223 253 120 Endress Hauser...
Page 123: ...Liquisys M CCM223 253 Endress Hauser 123...
Page 124: ...www addresses endress com 71212626...