Liquistation CSF39
Operation
Hauser
95
Menu/Setup/Inputs
Function
Options
Info
Reset totalizer
Selection
• Manual
• Automatic
• At program start
Factory setting
Manual
Manual
Reset the counter manually.
Automatic
The counter is reset automatically at
intervals.
At program start
The counter is reset at program start.
Having selected
Reset totalizer
Manual
Reset totalized flow
Action
The totalized flow currently calculated is set
to zero when the counter is reset.
Having selected
Reset totalizer
Automatic
Interval
Selection
• Daily
• Weekly
• Monthly
Factory setting
Daily
Daily
If a daily interval is selected, set the
Time
.
Weekly
If a weekly interval is selected, set the
Day
of week
and the
Time
.
Monthly
If a monthly interval is selected, set the
Day
of month
and the
Time
.
Time
00:00:00 ... 23:59:59
HH:MM:SS
Factory setting
12:00:00 HH:MM:SS
Having selected
Input variable
Rainfall
Signal slope
Selection
• Low-High
• High-Low
Factory setting
Low-High
Preselect the level change of the signal.
Unit
Selection
• mm
• inch
Factory setting
mm
Select the unit.
Meas. value format
Factory setting
#.#
Specify the number of decimal places.
1 Impulse =
0.00 to 5.00 mm
Factory setting
1.0 mm
Definition of the pulse value, limits are
calculated depending on the unit. The
correct switch value is provided in the
Operating Instructions of your rain gage.
Intensity
Selection
• mm/min
• mm/h
• mm/d
Factory setting
mm/min
Select the intensity per minute, hour or day
according to your requirements.
Totalized rainfall
Totalized rainfall
- - -
The totalized rainfall is displayed.