Proline Promag P 500 HART
Installation
Hauser
25
1
2
3
2
A0029344
1
EPD electrode for empty pipe detection
2
Measuring electrodes for signal detection
3
Reference electrode for potential equalization
Measuring devices with tantalum or platinum electrodes can be ordered without an
EPD electrode. In this case, empty pipe detection is performed via the measuring
electrodes.
Inlet and outlet runs
If possible, install the sensor upstream from fittings such as valves, T-pieces or elbows.
Observe the following inlet and outlet runs to comply with accuracy specifications:
≥ 5 × DN
≥ 2 × DN
A0028997
7
Order code for "Design", option A "Insertion length short, ISO/DVGW until DN400, DN450-2000 1:1" and
order code for "Design", option B "Insertion length long, ISO/DVGW until DN400, DN450-2000 1:1.3"
≥ 0 × DN
A0032859
8
Order code for "Design", option C "Insertion length short ISO/DVGW until DN300, w/o inlet and outlet
runs, constricted meas.tube"
Installation dimensions
For the dimensions and installation lengths of the device, see the "Technical
Information" document, "Mechanical construction" section.