background image

Page 2

Safety Information

DON'T:

•  Use the exercise system with the equipment compartment door 

removed.

•  Place electrical appliances within 1.5 m (5 feet) of the exercise 

system.

•  Use an extension cord to connect the exercise system to its power 

source. The cord may not be properly grounded and the connection is 

a shock hazard. An extension cord may cause a voltage drop, which 

will cause overheating of the jet pump motor and motor damage.

•  Attempt to open the electrical control box. There are no user serviceable 

parts inside.     

RISKS TO AVOID

DANGER - RISK OF INJURY

•  To reduce the risk of injury to persons, DO NOT remove suction fittings 

(filter standpipes) located in the filter compartment. 

•  The suction fittings in the exercise system are sized to match the 

specific water flow created by the pump. Never replace a suction fitting 

with one rated less than the flow rate marked on the original suction 

fitting.

•  There is a danger of slipping and falling. Remember that wet surfaces 

can be very slippery. Take care when entering or exiting the exercise 

system.

•  Never operate exercise system if the suction fittings are broken or 

missing.

•  People with infectious diseases should not use the exercise system.
•  Keep any loose articles of clothing, long hair, or hanging jewelry away 

from rotating jets or other moving components. Long hair should be 

tied up or placed under a bathing cap.

•  Safe water temperature for aquatic exercise is approximately  

29.5°C (85°F).

•  DO NOT use this exercise system alone.

INCREASED SIDE EFFECTS OF MEDICATION

•  The use of drugs or alcohol may cause unconsciousness with the 

possibility of drowning.

•  Persons using medications should consult a physician before using 

a exercise system; some medication may cause a user to become 

drowsy, while other medication may affect heart rate, blood pressure, 

and circulation.

•  Persons taking medications which induce drowsiness, such as 

tranquilizers, antihistamines, or anticoagulants should not use the 

exercise system.

HEALTH PROBLEMS AFFECTED BY EXERCISE 

SYSTEM USE

•  Pregnant women should consult a physician before using exercise 

system.

•  Persons suffering from obesity, or with a medical history of heart 

disease, low or high blood pressure, circulatory system problems, or 

diabetes should consult a physician before using exercise system.

UNCLEAN WATER

•  Keep the water clean and sanitized with correct chemical care. The 

recommended levels for your 

SWIMCROSS 

exercise system are:

Free Available Chlorine:  

1.0-5.0 ppm

Total Alkalinity:

80-120 ppm

Water pH:

7.2-7.8

Calcium Hardness:

50-150 ppm

•   Refer to Water Quality and Maintenance section for complete 

instructions.

IMPORTANT: 

Turn on the swim jets on high for a least ten minutes after 

adding ANY exercise system water chemicals into the swim area.
Clean the filter cartridges monthly to remove debris and mineral buildup 

which may affect the performance of the jets, limit the flow, or trip the 

high limit thermostat, which will turn off the entire exercise system.

AVOIDING THE RISK OF HYPERTHERMIA

Prolonged immersion in hot water can result in HYPERTHERMIA, a 

dangerous condition which occurs when the internal temperature of 

the body reaches a level above normal 37°C (98.6°F). The symptoms 

of hyperthermia include unawareness of impending hazard, failure 

to perceive heat, failure to recognize the need to exit the exercise 

system, physical inability to exit the exercise system, fetal damage 

in pregnant women, and unconsciousness resulting in a danger of 

drowning. 

WARNING

The use of alcohol, drugs, or medication can greatly increase the risk of 

fatal hyperthermia in exercise systems.

TO REDUCE THE RISK OF INJURY

•  The water in the exercise system should never exceed 40°C (104°F). 

Water temperatures between 26°C and 40°C (79°F and 104°F) are 

considered safe for a healthy adult. The lower water temperatures 

are recommended for extended use (exceeding ten minutes) and for 

young children. Extended use can cause hyperthermia.  

•  Pregnant or possibly pregnant women should limit exercise system 

water temperatures to 29.5°C (85°F consult a physician prior to using 

this product. Failure to do so may result in permanent injury to your 

baby.

•  Do not use exercise system having water temperatures over 36°C 

(100°F) immediately following strenuous exercise.

•  Keep all breakables, especially glass, away from this exercise 

system.

•  Never insert any objects into any openings.
•  Keep all chemicals away from children and pets.
•  DO NOT stack chemicals on top of one another.
•  NEVER MIX CHEMICALS.
•  Sanitizing chemicals must be stored separately from balancing 

chemicals.

Summary of Contents for X2000 SwimCross

Page 1: ...X2000 SwimCross System OWNER S MANUAL 50HZ by Endless Pools...

Page 2: ...________________ DATE INSTALLED ______________________________________ DEALER _____________________________________________ ADDRESS ____________________________________________ TELEPHONE _____________...

Page 3: ...ALL OFF MEMORY ON 16 SPA SIDE CONTROL PANEL 17 SETTINGS 17 INVERT SCREEN 19 TEMPERATURE CONTROL 19 JETS CONTROL 19 LIGHT CONTROL 20 FILTER CYCLES 20 POLLING 20 ALL OFF MEMORY ON 20 WI FI IN TOUCH OPT...

Page 4: ...qualified service personnel Do not attach an external antennae to an exercise system audio system unless installed by a licensed electrician in accordance with your National Electric Code WARNING To...

Page 5: ...high blood pressure circulatory system problems or diabetes should consult a physician before using exercise system UNCLEAN WATER Keep the water clean and sanitized with correct chemical care The reco...

Page 6: ...of the control box by the exercise system owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to...

Page 7: ...to a source of water Do not use the exercise system above a finished living area due to the risk of water damage The exercise system is not designed for in floor installation However it is compatible...

Page 8: ...When a small reach is needed for the final placement of your system a boom truck is ideal Atelehandler vehicle can off load traverse property and place your system in a more challenging situation or...

Page 9: ...concrete pad or structurally sound deck able to support the dead weight found in the specification chart on the back page WARNING The X2000 Model must not be shimmed in any manner 10 cm 226 cm 610 cm...

Page 10: ...our exercise system has been filled with water turn it on and test all of the circuit breakers IMPORTANT If breaker immediately trips verify that the wires are correctly connected Breaker should be te...

Page 11: ...nds then push the breaker switch to the OFF down position to ensure that it has completely disengaged then push the breaker switch to the ON up position If you don t wait 30 seconds the fitness system...

Page 12: ...he T spacer then remove the T spacer Loosen the 4 screws on the right side corner spacer but do not remove 3 Lift panel and slide left until panel is no longer behind corner 4 While holding panel firs...

Page 13: ...side Water Feature Levers adjust the amount of water that flows from the water features Jet pump 1 must be on for water feature to work 4 Swim side Water Feature Levers adjust the amount of water that...

Page 14: ...ystem is equipped with two air valves The air valves will add or remove air to the hydromassage jet system Rotate valve to see which hydromassage jets are affected QUICK START UP INSTRUCTIONS BEFORE Y...

Page 15: ...of the spa side is complete To turn off the jets press the jets button on the spa side control panel If you do not feel a steady stream of water from your jets refer to the instructions for priming th...

Page 16: ...confirm When in Economy mode the heating set point will be reduced by 11 C 20 F which means that the heating system will not come on during the set time unless the temperature falls 11 C 20 F below th...

Page 17: ...ttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the parameters and middle left lit button to move between parameters P...

Page 18: ...and condition of your exercise system and on outside temperatures The set temperature of the swim side water will automatically be 29 5 C 85 F the first time power is applied This is the setting prog...

Page 19: ...e devices See Wi Fi in the spa side Settings section to connect your swim side to your home Wi Fi network For instruction on how to download theApp to your device search gecko in touch in yourApp stor...

Page 20: ...ing set point will be reduced by 20 F 11 C which means that the heating system will not come on during the set time unless the temperature falls 20 F 11 C below the set temperature The filtration sche...

Page 21: ...he time format change the year date and time Use the or buttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the paramete...

Page 22: ...atures The set temperature of the spa side water will automatically be 38 0 C 100 F the first time power is applied This is the setting programmed at the factory After the spa side has been set up and...

Page 23: ...d for 1 minute purge cycle back to back FILTER CYCLE SUSPENSION The filter cycle will be suspended every time a jet pump or light is activated manually during the filter cycle time The suspension will...

Page 24: ...ir proper containers Don t inhale fumes or allow chemicals to come in contact with your eyes nose or mouth Wash your hands immediately after use Follow the emergency advice on the product label in cas...

Page 25: ...er iron and manganese will increase Minimize evaporation by keeping the cover on the exercise system whenever possible High iron or copper content in the water may produce green or brown stains on the...

Page 26: ...FAC chlorine does not have an odor whereas combined spent chlorine chloramines has a strong chlorine odor that can be eliminated by shocking the water IMPORTANT There are several forms of stabilized...

Page 27: ...quires changing due to the buildup of soap in the water Typically soap will cause the exercise system water to foam when the jets are used Soap is introduced into the exercise system water from two so...

Page 28: ...to keep your exercise system filter cartridges clean and free of particles to ensure proper water flow Clean filters enables the hydrotherapy system to function properly and allows for more efficient...

Page 29: ...side the exercise system remains at the selected temperature The energy efficiency of the exercise system may also decrease during these cold periods as the heater will cycle more frequently As an add...

Page 30: ...ners out of the reach of children and use care when applying EXERCISE SYSTEM CABINET All exercise systems use the exclusive all climate cabinet designed for years of performance The unique design is m...

Page 31: ...following factors Thermal overload Although mass produced not all thermal overload cutoffs are exactly the same Some are more sensitive than others and will shut the pump off at lower temperatures Hi...

Page 32: ...r Overused or old water Clean filters Shock exercise system with sanitizer Add sanitizer Adjust pH and or alkalinity to recommended range Run jets pump s and clean filters Drain and refill the exercis...

Page 33: ...cartridge Jet blocked Clogged suction or skimmer basket Open air valve Open any closed water valves Clean filter cartridge Remove jet face eyeball and clean orifice Clean suction cover or skimmer bas...

Page 34: ......

Page 35: ......

Page 36: ...5V 3N 24A 50HZ Three phase 24 amp phase GFCI protected circuit F o o t p r i n t d i m e n s i o n s S w i m s i d e e f f e c t i v e f i l t e r a r e a H e i g h t S w i m s i d e h e a t e r W a t...

Reviews: