background image

Page 12

Getting Started

START-UP

Your 

SWIMCROSS 

exercise system has been thoroughly tested during 

the manufacturing process to ensure reliability and long-term customer 

satisfaction. A small amount of water may have remained in the 

plumbing after testing and, as a result, may have spotted the exercise 

system shell or the exercise system siding prior to delivery. Before filling 

the exercise system, wipe the exercise system shell clean with a soft 

rag. The following instructions must be read and followed exactly to 

ensure a successful start-up or refill.

CAUTIONS

•  DO NOT CONNECT POWER TO AN EMPTY exercise system. 

Power to the exercise system automatically activates critical 

components within the exercise system, such as controls, heaters, and 

other systems. If power is supplied to these components prior to both 

swim side and spa side being filled, the components will be damaged, 

and this may result in a non-warranty component failure.

•  DO NOT 

use your exercise system after filling until all of the steps 

listed below are completed.

•  DO NOT 

add chlorine if treating your exercise system with 

polyhexamethylene biguanide (Biguanide, PHMB, eg. BaquaSpa

®

sanitizer.

•  DO NOT

 use a salt-generated chlorine system, this will damage 

components and is not covered under your warranty.

•  Before filling your exercise system for the first time, remove the 

equipment compartment door and check to ensure that the unions 

on either side of the pump(s) and heater are hand-tight and the slide 

valves are open.
1.  

CLOSE DRAIN, remove the filter compartment grill skimmer 

tray and one filter (pg. 24). 

a. Fill your swim side through the filter compartment using the 

CleanScreen

 pre-filter (optional from dealer) that attaches to 

your garden hose. The water level of your swim side should be 

maintained at a level 15 cm (6") below the top of the 

SWIMCROSS

 

Exercise System. Reinstall the filter, skimmer tray, and grill once the 

swim side is filled. 

b. Fill your spa side through the filter compartment (lift filter basket up 

and out first) using the 

CLEANSCREEN

 pre-filter (optional from 

dealer) that attaches to your garden hose. The water level of your 

spa side should be maintained at 2.5 cm (1") above the highest jet.  

IMPORTANT:

 

Watkins Wellness does not recommend that the 

exercise system be filled with “softened” water, as this may damage 

the exercise system’s equipment.

2.  

AFTER THE EXERCISE SYSTEM HAS BEEN FILLED

 with 

water and the equipment compartment door is secured, power 

must be applied to the exercise system. 
•  FIRST activate power to the subpanel from the main house panel.
•  NEXT open the door of the electrical subpanel and reset the 

GFCI breakers.

•  FINALLY, close and secure the subpanel door.

3.  

TO CHECK THE OPERATION OF THE HYDROMASSAGE JET 

SYSTEM IN SPA 

and to purge any remaining air from the system 

complete the following steps:
•  Press the jets buttons on spa side control panel placing all 

hydromassage jets on. 

•  Once the jet system is fully operational (as indicated by strong, 

non-surging jets), priming of the spa side is complete.

•  To turn off the jets, press the jets button on the spa side control 

panel.

•  If you do not feel a steady stream of water from your jets, refer 

to the instructions for priming the pump in the exercise system 

TROUBLESHOOTING section.

4. 

TO CHECK THE OPERATION OF THE SWIM JET SYSTEM  

and to purge any remaining air from the system complete the 

following steps:
•  Press the jets buttons on spa side control panel placing all swim 

jets on. 

•  Once the jet system is fully operational (as indicated by strong, 

non-surging jets), priming of the spa side is complete.

•  To turn off the jets, press the jets button on the spa side control 

panel.

•  If you do not feel a steady stream of water from your jets, refer 

to the instructions for priming the pump in the exercise system 

TROUBLESHOOTING section.

5.  

SET THE TEMPERATURE CONTROL 

to the desired temperature 

between 15°C (59°F) and 40°C (104°F) on both the swim side and 

the spa side control panels, then place the exercise system cover 

on the exercise system and allow the water temperature to stabilize 

approximately 0.5°C (1°F) per hour. Make sure you secure the cover 

in place. Periodically check the exercise system water temperature. 

When the water temperature reaches desired temperature, 

proceed to the next step. The exercise system temperature is pre-

programmed to reach 29.5°C (85°F) on the swim side and 

38.0°C (100°F) on the spa side. You may change the water 

temperature by pressing the 

 button on each control panel 

to raise the temperature, or lower temperature by pressing the 

▼button. 

6.  

USING A TEST STRIP AND APPLICABLE CHEMICALS 

adjust 

Total Alkalinity (TA) to 80-120 ppm, Calcium Hardness (CH) to 

50-150 ppm, then exercise system water pH to between 7.2 

and 7.8. These procedures are listed in the “Water Quality and 

Maintenance” section.

OPERATION NOTE:

 

Adjusting the Total Alkalinity as the first step 

is important, as out-of balance TA will affect your ability to adjust the 

pH correctly and will prevent the sanitizer from operating effectively. 

7.  

SUPERCHLORINATE THE EXERCISE SYSTEM WATER 

by 

adding 1½ teaspoons of chlorine (sodium dichlor) per 950 liters  

(250 gallons) of water while running the swim jets at high speed for 

10 minutes in the swim side. Disperse the chemicals in the swim 

area away from the walls. Add into filter area on the spa side while 

running both jets for 10 minutes. 

8.  

TEST THE EXERCISE SYSTEM WATER FOR CHLORINE 

RESIDUAL.  

If the residual is between 1 and 5 ppm on the test 

strips, go on to the next step. If the residual is less than 1 ppm, 

activate the swim jets (on swim side) on high for another 10 minutes 

and add more chlorine as needed, or if needed activate the jets on 

the spa side and run both jets for 10 minutes.

WARNING:

 

High sanitizer levels can cause discomfort to the user’s 

eyes, lungs and skin. Always allow the sanitizer level to fall to the 

recommended range before using the exercise system.

9.  

RECHECK

 the Total Alkalinity (TA) 80-120 ppm, Calcium Hardness 

(CH) 50-150 ppm, and the pH

 must be

 between 7.2 and 7.8.  

The exercise system is ready for use when the exercise system 

water has circulated and the bromine level remains between 1 and 2 

ppm or chlorine level remains between 1 and 5 ppm.

Summary of Contents for X2000 SwimCross

Page 1: ...X2000 SwimCross System OWNER S MANUAL 50HZ by Endless Pools...

Page 2: ...________________ DATE INSTALLED ______________________________________ DEALER _____________________________________________ ADDRESS ____________________________________________ TELEPHONE _____________...

Page 3: ...ALL OFF MEMORY ON 16 SPA SIDE CONTROL PANEL 17 SETTINGS 17 INVERT SCREEN 19 TEMPERATURE CONTROL 19 JETS CONTROL 19 LIGHT CONTROL 20 FILTER CYCLES 20 POLLING 20 ALL OFF MEMORY ON 20 WI FI IN TOUCH OPT...

Page 4: ...qualified service personnel Do not attach an external antennae to an exercise system audio system unless installed by a licensed electrician in accordance with your National Electric Code WARNING To...

Page 5: ...high blood pressure circulatory system problems or diabetes should consult a physician before using exercise system UNCLEAN WATER Keep the water clean and sanitized with correct chemical care The reco...

Page 6: ...of the control box by the exercise system owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to...

Page 7: ...to a source of water Do not use the exercise system above a finished living area due to the risk of water damage The exercise system is not designed for in floor installation However it is compatible...

Page 8: ...When a small reach is needed for the final placement of your system a boom truck is ideal Atelehandler vehicle can off load traverse property and place your system in a more challenging situation or...

Page 9: ...concrete pad or structurally sound deck able to support the dead weight found in the specification chart on the back page WARNING The X2000 Model must not be shimmed in any manner 10 cm 226 cm 610 cm...

Page 10: ...our exercise system has been filled with water turn it on and test all of the circuit breakers IMPORTANT If breaker immediately trips verify that the wires are correctly connected Breaker should be te...

Page 11: ...nds then push the breaker switch to the OFF down position to ensure that it has completely disengaged then push the breaker switch to the ON up position If you don t wait 30 seconds the fitness system...

Page 12: ...he T spacer then remove the T spacer Loosen the 4 screws on the right side corner spacer but do not remove 3 Lift panel and slide left until panel is no longer behind corner 4 While holding panel firs...

Page 13: ...side Water Feature Levers adjust the amount of water that flows from the water features Jet pump 1 must be on for water feature to work 4 Swim side Water Feature Levers adjust the amount of water that...

Page 14: ...ystem is equipped with two air valves The air valves will add or remove air to the hydromassage jet system Rotate valve to see which hydromassage jets are affected QUICK START UP INSTRUCTIONS BEFORE Y...

Page 15: ...of the spa side is complete To turn off the jets press the jets button on the spa side control panel If you do not feel a steady stream of water from your jets refer to the instructions for priming th...

Page 16: ...confirm When in Economy mode the heating set point will be reduced by 11 C 20 F which means that the heating system will not come on during the set time unless the temperature falls 11 C 20 F below th...

Page 17: ...ttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the parameters and middle left lit button to move between parameters P...

Page 18: ...and condition of your exercise system and on outside temperatures The set temperature of the swim side water will automatically be 29 5 C 85 F the first time power is applied This is the setting prog...

Page 19: ...e devices See Wi Fi in the spa side Settings section to connect your swim side to your home Wi Fi network For instruction on how to download theApp to your device search gecko in touch in yourApp stor...

Page 20: ...ing set point will be reduced by 20 F 11 C which means that the heating system will not come on during the set time unless the temperature falls 20 F 11 C below the set temperature The filtration sche...

Page 21: ...he time format change the year date and time Use the or buttons to choose the setting that you want to adjust and select it by pressing middle left lit button Use the or buttons to change the paramete...

Page 22: ...atures The set temperature of the spa side water will automatically be 38 0 C 100 F the first time power is applied This is the setting programmed at the factory After the spa side has been set up and...

Page 23: ...d for 1 minute purge cycle back to back FILTER CYCLE SUSPENSION The filter cycle will be suspended every time a jet pump or light is activated manually during the filter cycle time The suspension will...

Page 24: ...ir proper containers Don t inhale fumes or allow chemicals to come in contact with your eyes nose or mouth Wash your hands immediately after use Follow the emergency advice on the product label in cas...

Page 25: ...er iron and manganese will increase Minimize evaporation by keeping the cover on the exercise system whenever possible High iron or copper content in the water may produce green or brown stains on the...

Page 26: ...FAC chlorine does not have an odor whereas combined spent chlorine chloramines has a strong chlorine odor that can be eliminated by shocking the water IMPORTANT There are several forms of stabilized...

Page 27: ...quires changing due to the buildup of soap in the water Typically soap will cause the exercise system water to foam when the jets are used Soap is introduced into the exercise system water from two so...

Page 28: ...to keep your exercise system filter cartridges clean and free of particles to ensure proper water flow Clean filters enables the hydrotherapy system to function properly and allows for more efficient...

Page 29: ...side the exercise system remains at the selected temperature The energy efficiency of the exercise system may also decrease during these cold periods as the heater will cycle more frequently As an add...

Page 30: ...ners out of the reach of children and use care when applying EXERCISE SYSTEM CABINET All exercise systems use the exclusive all climate cabinet designed for years of performance The unique design is m...

Page 31: ...following factors Thermal overload Although mass produced not all thermal overload cutoffs are exactly the same Some are more sensitive than others and will shut the pump off at lower temperatures Hi...

Page 32: ...r Overused or old water Clean filters Shock exercise system with sanitizer Add sanitizer Adjust pH and or alkalinity to recommended range Run jets pump s and clean filters Drain and refill the exercis...

Page 33: ...cartridge Jet blocked Clogged suction or skimmer basket Open air valve Open any closed water valves Clean filter cartridge Remove jet face eyeball and clean orifice Clean suction cover or skimmer bas...

Page 34: ......

Page 35: ......

Page 36: ...5V 3N 24A 50HZ Three phase 24 amp phase GFCI protected circuit F o o t p r i n t d i m e n s i o n s S w i m s i d e e f f e c t i v e f i l t e r a r e a H e i g h t S w i m s i d e h e a t e r W a t...