Summary of Contents for VAAR1000

Page 1: ...ater Range Stock Ref N 448469 VAAR500 448470 VAAR750 448471 VAAR1000 448472 VAAR1250 448473 VAAR1500 Installation and Wiring Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS ...

Page 2: ...a way that it is impossible for anyone using a bath or shower to touch the controls The appliance should not be located under or in front of a power supply socket This appliance must be connected to the supply by fixed wiring The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm Before carrying out any work on the heater It mus...

Page 3: ...ls 2 1 It is important that the heater IS FIXED FIRMLY TO A SOLID AND LEVELLED WALL 2 2 Make sure that there is a socket near the area where you are going to place it 2 3 Take out from the box the pattern to see the exact position of the mounting screws 3 4 SCREWS 4 2 INSTALLATION INSTRUCTIONS PLACE THE HEATER W 500 750 1000 1250 1500 A mm 420 420 420 420 420 B mm 246 246 246 246 246 C mm 159 319 ...

Page 4: ...and any combustible material such as curtains furnitures etc 7 5 3 TECHNICAL INFORMATION Manual programming function 7 pre set programmes Configure your own heater program Comfort economic antifreeze modes The controls can be locked Weekly programming ON OFF Luminous display This heater must be used on an supply only and the voltage marked on the heater must correspond to the supply voltage Before ...

Page 5: ...N KEYS OK 5 ON OFF FOR THE DISPLAY 6 ECONOMIC LED 7 COMFORT LED 8 PROGRAM SETTING LEDS 1 2 3 4 5 6 7 8 5 1 START UP Press Stand by Press Pr Hd 1 2 5 2 MODE MANUAL 1 2 3 Press The room temperature appears The led is lit up 17 5 c 5 PROGRAMMING THE HEATER ...

Page 6: ...eating situations that you may need The 7 plans are described below in the table nº 1 The Plan nF is programmed for periods when you are away from your home during long periods of time and would like to protect it against freezing The green economy LED will flash TABLE Nº 1 Working Days Weekend Comfort Economy Antifreeze The UE Plan is a heating plan desired for weekends With this plan the heater ...

Page 7: ...e language english french spanish pressing or or Press Press 6 7 Press Press Programme the day of the week or Press 00 00 Hour 23 00 dAY dd Mo 8 9 Press Press Mark the desired comfort temperature or Press tº C 22 0 ºc 10 11 Press Press Mark the desired economy temperature or Press tº E 18 0 ºc Press ...

Page 8: ... action this plan Press 5 4 PLAN ACCORDING TO YOUR REQUIREMENTS If none of the 7 programmes correspond to your heating needs we are going to explain how you can configure your own heating system plan 1 2 3 Press 2 seg Press Hour PLAn Press Example Working Days Weekend Comfort Economy Antifreeze ...

Page 9: ... days monday to friday leds will light up In our case the first economy period starts at 9 00 h 9 6 Now we are going to introduce the start of the first comfort period from monday to friday The comfort first period P1 and days monday to friday leds will light up In our case the first comfort period starts at 6 00 h 4 5 Press Choose the programme PLCF or Press PL CF ...

Page 10: ...rday and sunday 10 11 Press Choose 09 00 h or Press 09 00 12 Now we are going to programme period P2 and period P3 Press Choose 14 00 h or Press 14 00 Press Choose 18 00 h or Press 18 00 14 13 Press Choose 20 00 h or Press 20 00 Press Choose 24 00 h or Press 24 00 15 ...

Page 11: ... If you do not require a set time period you must put the hour of this period at 00 00 As you can see we have not defined a third period between saturday and sunday To switch off the display press the button 00 00 00 00 Press If you wish to illuminate the display again press any search button This option is cancelled when the heater is programmed in the anti freeze plan PLAH IMPORTANT ...

Page 12: ...ate the function of locking the controls touch simultaneously the keys Fig 1 To deactivate the function of locking the controls touch simultaneously the keys Fig 2 Loc unlo FIG 1 FIG 2 10 POWER CONSUMPTION INDICATION NOTE If you wish to reset the counter repeat steps 1 4 and press 3 seg the key 1 2 3 Press 3 seg Press Hour WAt Press 4 5 The approximate consumption in KW will be indicated for examp...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ... found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to misu...