ECO-V 150 Pool Pump 
 
 
 
 
 
Owners Manual Installations 
 
 
 
 
 
 
 

Product Image to be supplied Joey. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This equipment must be installed and serviced by a qualified technician. 
Improper installation can create electrical hazards which could result in property 
damage, serious injury or death. Improper installation will void the warranty. 
 
Notice to Installer 
This manual contains important information about the installation, operation and safe 
use of this product. Once the product has been installed this manual must be given 
to the owner/ operator of this equipment. 
 
 
 
 
 
 

Summary of Contents for Hydrostorm ECO-V 150

Page 1: ...lation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment ...

Page 2: ...acturing our pumps a few simple precautions during installation will ensure years of trouble free operation 1 The pump suction line should be not smaller than 1 1 2 40mm imperial 2 The suction line is to have as few bends or elbows as possible There must not be an air trap on the suction line 3 Use only the pump barrel unions supplied with the pump 4 Bolt the pump to the required position prevent ...

Page 3: ...y or death To reduce the risk of electric shock the electrician must comply with installation instructions and must bond the pump accordingly In addition the licensed electrician must also conform to local electrical codes for bonding requirements ELECTRICAL CONNECTION Check that the information on the nameplate corresponds to the power supply Employ a competent electrician to ensure wiring instal...

Page 4: ...ic voltage Work may only be performed on each pump or on the equipment connected to it after disconnecting them from the mains power and after disconnecting the starting device 7 The user should make sure that assembly and maintenance tasks are carried out by qualified authorized persons and that these persons have first carefully read the instructions for service and installation 8 The operating ...

Page 5: ...ncy of 60 Hz Navigation Overview Increases decreases selected value Pressing any key following a change accepts the current value displayed inside the setting Refer Joey re panel image Figure 1 Waterco ECO V 150 User Interface Button Descriptions CAUTION If power is connected to the Waterco ECO V 150 motor pressing any of the following buttons referred to in section 2 could result in the motor sta...

Page 6: ...ress the STOP key the Waterco ECO V 150 will automatically start and run the programmed default schedule shown in the chart above This feature ensures that the Waterco ECO V 150 will re start in the event of a power outage 3 2 Quick Start Guide User defined custom schedule A Waterco ECO V 150 user can set the program DURATION and SPEED for STEP 1 STEP 2 STEP 3 OVERRIDE keys Note Waterco ECO V 150 ...

Page 7: ...ess START to run the Waterco ECO V 150 based on the programmed 24 hour schedule 7 Pressing the STOP button will stop the Waterco ECO V 150 Note The Waterco ECO V 150 can only be set to operate on a 24 hour schedule If a user attempts to program a schedule with a combined duration for all three steps greater than 24 hours the Waterco ECO V 150 software will retain the current STEP time duration onl...

Page 8: ...Waterco ECO V 150 at the lowest speed for the longest duration is the best strategy to minimize energy consumption However conditions may require running the Waterco ECO V 150 at a higher speed for some duration of time each day to maintain proper filtration to achieve satisfactory sanitation The User Interface is located on top of the Waterco ECO V 150 To the right of the STEP buttons is the OVER...

Page 9: ...e controller is designed to operate with 208 230 Vrms single phase power The Waterco ECO V 150 is designed to handle either a bare wire connection or a quick disconnect connection The quick disconnect tab is 0 250 and will handle any commonly available mating connectors For a direct wire connection the wire insulation should be stripped to a length of approxi mately 0 33 The terminal block is capa...

Page 10: ...hen installing servicing or repairing electrical components Observe all warning notices posted on the existing equipment Waterco ECO V 150 and in these installation instructions Refer Joey re chart image Figure 3 Mains Connection Diagram ...

Page 11: ... Warning Access to these terminals is in close proximity to the mains connectors which carry line voltage capable of causing personal injury or damaging the equipment if contact is made Power should be turned off when accessing this area Refer Joey re chart image Figure 5 Digital Input connector ...

Page 12: ...6 User Interface Operation 6 1 LED and Function Overview Refer Joey re chart image Figure 6 LED Functionality Table ...

Page 13: ...e Schedule Caution If power is connected to the Waterco ECO V 150 motor pressing any of the following buttons referred to in this section 6 3 could result in the motor starting Failure to recognize this could result in personal injury or damage to equipment Set the DURATION and SPEED for the Waterco ECO V 150 using the keys on the User Interface The schedule is based on a 24 hour schedule and will...

Page 14: ...t will always take priority over any previous settings In the event a user attempts to program with a combined duration greater than 24 hours the current STEP setting will be retained whereas the other two STEP settings will be cleared to zero hours requiring the user to reset them Prior to beginning the actual programming process it is advisable for the user to review the planned schedule as outl...

Page 15: ... be stored in the controller Should a power outage occur the Waterco ECO V 150 will automatically re start at STEP 1 when power is restored 2 The Waterco ECO V 150 will always run the PRIMING sequence when it starts from the OFF state including when it automatically restarts following a power outage The default Prime setting is defined in the Priming section of this document 3 The Waterco ECO V 15...

Page 16: ...l start the 24 hour schedule from STEP 1 Note If a digital input provided from an external source is detected the Waterco ECO V 150 will start running on the STEP 1 STEP 2 STEP 3 or OVERRIDE speed corresponding to the digital input Upon removing the digital input provided from an external source the Waterco ECO V 150 will stop and the user will need to press START to begin the 24 hour schedule ope...

Page 17: ...unning at that time The OVER RIDE duration will not affect the start or stop times of the 24 hour schedule For example if OVERRIDE runs during a period overlapping with a later part of STEP 1 and an early part of STEP 2 the start time of STEP 3 is not affected Note Pressing Holding OVERRIDE key for more than three 3 seconds will cancel OVERRIDE mode Note During the OVERRIDE mode the Waterco ECO V ...

Page 18: ...to set Schedule Advance mode 1 With the Waterco ECO V 150 stopped press and hold the START key for more than three 3 seconds The START LED will blink at a rate of one second per pulse The DURATION setting LED and respective bar graph LED will remain turned ON until the Schedule Advance mode is complete Refer Joey re chart image 2 Press the UP or DOWN arrows to set the desired delay time after whic...

Page 19: ...or will only temporarily stop 4 min it will then restart The Waterco ECO V 150 user interface has a key lockout feature to prevent unwanted changes to the settings To lock the keys hold down the STEP 1 STEP 2 and STEP 3 buttons all at the same time for at least three seconds The active LEDs for STEP 1 STEP 2 and STEP 3 will blink for 30 seconds indicating that the keypad is locked The user can unl...

Page 20: ...h Digital Serial Input Caution Temporary stop functionality only works while the Waterco ECO V 150 is being controlled by a digital or serial input If the motor is being controlled by the integrated key pad and STOP is pressed the motor will stop and remain stopped The Waterco ECO V 150 has a temporary stop feature that will immediately stop the Waterco ECO V 150 when being controlled by a serial ...

Page 21: ...ressed This can be confirmed by verifying that the START LED is illuminated In the event that the outside air temperature drops below a set threshold the Waterco ECO V 150 will automatically turn on assuming the START button has been pressed and circulate the pool water The Freeze Protection will run according to the following conditions utilizing the factory default settings Freeze Protection tur...

Page 22: ...e Waterco ECO V 150 to a System Level Controller This concept can be applied to a solar system or any other type of control system Note There is no schedule for digital inputs The timing for each speed is controlled directly by the digital inputs Note The digital inputs have the highest priority amongst all the inputs i e keypad serial or digital Therefore the serial commands as well as the User I...

Page 23: ...used to configure different settings for the Waterco ECO V 150 Each DIP switch and their corresponding function is defined in Table 5 Refer Joey re chart image Table 5 DIP Switch Functions Figure 8 DIP Switches 11 Care and Maintenance The Waterco ECO V 150 is both reliable and robust in harsh environments However this product does contain electronics that are cooled by a fan mounted to the Waterco...

Page 24: ...s The Waterco ECO V 150 reads the FAULT status and provides feedback to the user via the FAULT LED The Waterco ECO V 150 will illuminate the FAULTLED when a FAULT is present The Waterco ECO V 150 will stop and remain OFF when the FAULT is present Once the FAULT is cleared if the Waterco ECO V 150 was previously running it will automatically resume running the normal schedule Refer Joey re chart im...

Page 25: ...en the FAULT LED is blinking every one 1 second a FAULT is present in the user interface 5 When the FAULT has cleared the FAULT LED will turn OFF 6 Once the FAULT is cleared if the Waterco ECO V 150 was previously running it will automatically resume running the normal schedule Please see Section 14 for troubleshooting issues and their resolutions 13 Specifications Refer Joey re chart image Remove...

Page 26: ...le temperature is than 32O F 0O C and than 95O F 35O C The pump should never be operated outside of these temperatures or damage may occur WARNINGS FOR ASSEMBLY AND MAINTENANCE TASKS 1 Be especially careful that no water enters the motor or the electrical parts under voltage 2 Avoid all contact even accidental with the moving parts of the pump 3 Wait until the pump has stopped completely before ha...

Page 27: ...the complexity of the cases covered the instructions for installation use and maintenance contained in this manual do not attempt to examine all possible and imaginable cases of service and maintenance If supplementary instructions are required or if special problems 14 Troubleshooting Guide Warning Diagnosing certain symptoms may require close interaction with or in close proximity to components ...

Page 28: ...act your supplier or the nearest Waterco Limited branch for advice Failure to do this may void warranty Refer to warranty documentation supplied with pump All electrical work is to be carried out by a Qualified Electrician under no circumstances should you attempt repairs on the electrical components of Waterco Limited pumps unless you are qualified to do so ZZM1864 05 16 ...

Page 29: ......